Rated Voltage 21kv Mcov 17kv Creepage Distance 662mm Arrestor with Polymer Housed
Rated Voltage 21kv Mcov 17kv Creepage Distance 662mm Arrestor with Polymer Housed image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
| Type | YH5W5-21/56 | 4/10µS High current impulse kA | 65 |
| Rated voltage———kV | 21 | Lightning impulse withstand kV | 125 |
| MCOV —————-kV | 17 | Power frequency voltage withstand(dry/wet)kV | 50 |
| Nominal Current——-kV | 5 | 0.1S TOV————–kV | 25.2 |
| Residual voltage of steep impulse—-at 5kA(kV) | 60.5 | 1S TOV—————-kV | 24.15 |
| 8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 56 | 10S TOV—————kV | 23.1 |
| Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | / | 1200S TOV————-kV | 21 |
| 1mA D.C reference voltage (kV) | 29.7 | Creepage distance —-mm | 662 |
| Line discharge level | 1 | Material employed in series non-linear resistor | Zinc Oxide |
| 2mS long duration impulse current A | 250 | Material of housing | silicone rubber |
Working condition:
| Environment temperature: -40–+40 degree | |||||||
| altitude:<1000m | |||||||
| 48HZ<Rated frequency<62HZ | |||||||
| Power frequency voltage should not be more than continuous running voltage | |||||||
| Max wind speed should be less than 35m/s | |||||||
| Earthquake intensity should be less than 7 degree | |||||||
| If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Rated Voltage 21kv Mcov 17kv Creepage Distance 662mm Arrestor with Polymer Housed manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Electric Porcelain Housed 120kv Surge Arrester Without Gap
Kema Tested High Voltage Polymeric Thunder Arrester Lightning
IEC Standard 11kv 12kv 15kv Expulsion Porcelain Fuse Cutout
Pd2 33-36kv Porcelain Fuse Cutout
Lighting Arrester/Lightning Rod Lightning Arrestor
High Voltage Insulator Surge Arrester
Popular Lightning Arrester Products
Yh5w-9, Sharp Head 5kv 9ka Surge Arrester
42kv Metal Oxide Lightning Arrester for Overvoltage Protection
Hy10W Gapless Composite Inslulation Arrester
Popular Surge Arrester Products
High Quality Cheap 11kv Substation Lightning Arrester
Hy1.5W-0.28/1.3 Zinc-Oxide Arrester
Yh6w-24 Sharp Head 6kv 24ka Surge Arrester
20ka-40ka DC1000V Solar DC Surge Arrester
110V Outdoor Poe Polymer Silicone Housing Surge Protector with Disconnector
Gray Brown Surge Protector Arrester
Popular Surge Arresters Products
Kema Report Rated Voltage 18kv Moa Metal Oxide 3 Phase Lighting Arrester
Mv Composite Metal Oxide Surge Arrester Without Gaps
Polymer Housed Gapless Metal Oxide 66kv Power Surge Arrester
Hv Metal Oxide Porcelain Lighting Arrester with Garding Ring
Lightning Arrestor High Voltage Metal Oxide Station Surge Arrestor
250kv Substation Type Line Discharge Level 3 Ceramic Lightning Arrester
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters