Outdoor Electric Line Discharge Level 1 to 5 Porcelain Lighting Arrester 110kv
Outdoor Electric Line Discharge Level 1 to 5 Porcelain Lighting Arrester 110kv image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
| Type | Y10W5-108/281 |
| Rated Voltage———kV | 108 |
| MCOV —————-kV | 86 |
| Nominal Current——-kA | 10 |
| Residual voltage of steep impulse—-at 5kA(kV) | 325 |
| 8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 274 |
| Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 215 |
| 1mA D.C reference voltage (kV) | 157 |
| Line discharge level | 3 |
| 2mS long duration impulse current A | 850 |
| 4/10µS High current impulse kA | 100 |
| Lightning impulse withstand kV | 550 |
| Power frequency voltage withstand(dry/wet)kV | 230 |
| 0.1S TOV————–kV | 129.6 |
| 1S TOV—————-kV | 124.2 |
| 10S TOV—————kV | 118.8 |
| 1200S TOV————-kV | 108 |
| Creepage distance —-mm | 3906 |
| Material employed in series non-linear resistor | Zinc Oxide |
Working condition:
| Environment temperature: -40–+40 degree | |||||||
| altitude:<1000m | |||||||
| 48HZ<Rated frequency<62HZ | |||||||
| Power frequency voltage should not be more than continuous running voltage | |||||||
| Max wind speed should be less than 35m/s | |||||||
| Earthquake intensity should be less than 7 degree | |||||||
| If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Outdoor Electric Line Discharge Level 1 to 5 Porcelain Lighting Arrester 110kv manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Surge Protection Insulator SPD Arrester
Pole Mounted Isolating Switch for AC System
High Quality High Power Electrical Items Fuse Switch Pole Mounted
High Quality Metal Oxide Gapless Lightning Surge Protective Arrester
Outdoor Electric Switch Disconnector
List of Electrical Equipments 10ka 24kv-110kv Substation Lightning Arrester
Popular Lightning Arrester Products
Yh10W-45, Sharp Head 45kv 10ka Surge Arrester
Polymer Housed Gapless Surge Arrester From 3 Kv up to 36 Kv
Lug, Alum. 2 Hole Canton 394.5mcm
Popular Surge Arrester Products
110kv Silicon Type Surge Arrester Cma5ws-108/281
33kv High Voltage Drop out Type Lighting Arrester
Hot Sale 35kv Silicon Rubber Arrester
33kv-36kv High Voltage Low Price Equipment Solid and Durable Lightning Arrester
36kv Silicone Rubber Surge Protector Lightning Arrester
Popular Surge Arresters Products
5ka (3-36KV) Polymeric Housed Zinc Oxide Lightning Arresters Without Gaps
5ka 3-36kv Polymeric Housed Zinc Oxide Lightning Arresters Without Gaps
Outdoor Station Type 11kv-220kv Polymeric Lightning Arrester (type test)
3-36kv Polymeric Lightning Arresters/Surge Arrester with Gap &Gap-Less Polymer Housed
200kv Metal Oxide Surge Diverters for Electric Station
220kv Substation All Types of Zinc-Oxide Lighting Arrester up to 500kv
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters