AL/Cu    Conductor Dimension Color
Code
Die   Index Wire
Strip
Length
Temp. Rating
Stud
Size
(K) No.
of
Holes
in
Pad
(OD) (B) ( C) (L) (N) (E) (T)
36 400 kcmil ½ 0.56 2 1.19 2.26 1.62 6.15 0.63 1.75 0.43 Green 472 2 90oC
61 1/0 AWG 1 0.60 1.05 1.03 2.83 0.63 0.17 Tan 296 1- 1/16
62 2 1.11 1.85 1.52 6.07 1.75 0.39 Brown 299 2- 1/8
63 4/0 str. 0.85 1.39 1.17 5.19 0.30 White 298 1-5/8
105 1

   Must be used on both aluminum and copper conductors.
   Connectors must be clearly marked with wire size, die index, color code, and crimp location bands
   Must pre-filled with oxide inhibitor
   Must have color coded end caps are factory inserted in the barrels to match the die
color code and prevent foreign materials from entering the barrel.
   Must accommodate conductor types:
o  Aluminum Code Wire: Class B (Concentric, Compressed, Compact)
o  Copper Code Wire: Class B (Concentric, Compressed, Compact or Class C
o  Copper Clad Aluminum: Noted in the conductor accommodates as CCA

Application field

The surge arresters protect the network and their
equipment from overvoltages. They are of key importance
to improve the quality and reliability of the power supply.

 
 
 Design

Our surge arresters fulfil the requirements of
IEC60099-4.

 

Operating conditions
Ambient temperature : – 50°C up to + 50°C

 

Technical parameters
• Rated voltage Ur : 3 kV up to 36 kV
• Nominal discharge current : 10 kA
• High current impulse withstand : 100 kA
• Long duration current impulse withstand : 300 A
• Line discharge class : 1
• Short circuit withstand : 20 kA / 0,2 s

 

 Type  Unit HE 03 HE05 HE06 HE09 HE10 HE12 HE12/ R HE15 HE18 HE 18 /R HE21 HE24 HE24
/R
HE24
/2R
HE27 HE30 HE33 HE36 HE36
/ R
Rated voltage  kV eff
/ rms
3,3 5 6 9 10 12 12 15 18 18 21 24 24 24 27 30 33 36 36
Continuous operating voltage  kV eff
/ rms
2,8 4.25 5.1 7.65 8.4 10.2 10.2 12.7 15.3 15,3 17.5 20.0 20.0 20.0 22.5 25 27.5 30 30
 maximale Maximum residual voltage
5 kA 8/20
10kA 8/20
20kA 8/20
kV 
/ peak
15.4
16.4
18.1
14.3
15.2
16.8
15.4
16.4
18.1
26.4
28.1
31.1
27.5
29.3
32.4
30.8
32.8
36.2
30.8
32.8
36.2
40.7
43.3
47.8
46.2
49.1
54.3
46,2
49,1
54,3
56.1
59.7
66.0
61.2
65.1
71.9
61.2
65.1
71.9
61.2
65.1
71.9
72.2
76.8
84.9
76.2
81.1
89.6
87.2
92.8
102.5
91.7
97.5
107.5
91.7
97.5
107.7
Switching residual voltage at 500- 30/80 kV 
/ peak
8,0 12.1 13.0 22.3 23.3 26.1 26.1 34.4 39.0 39,0 47.5 51.8 51.8 51.8 61.1 64.5 73.8 77.5 77.5
Steep current impulse residual voltage at 10kA-1/2.5 kV  peak 10,8 16.4 17.7 30.3 31.6 35.4 35.4 46.8 53.0 53,0 64.5 70.3 70.3 70.3 82.9 87.6 100.2 105.3 105.3
Lighning impulse withstand level of the housing kV 1.2/50 95 110 125 170 200 170 200
Flexion dynamique (SSL) / Specified short-term load
Flexion statique (SLL) / Specified long-term load
N.m 125
100
250
200
125
100
250
200
Creepage distance mm 480 650 800 1200 1360 1200 1360
Height mm 165 205 245 325 365 325 365
Diameter mm 104 109 114
Weight (S3D2 option) kg 1,4 1.5 1.5 1.7 1.7 1.7 1.9 2.1 2.1 2,3 2.5 2.5 2.9 3.1 3.1 3.1 3,3 3,3 3,5

 

Option
NO option: supplied with bolts, washers, and
clamp for connection
IF option: electronic fault indicator using a red
flag for easy signalling
S3D2 option*: ground lead disconnector and
insulating bracket

 
 
 

Accessories
Metal bracket for horizontal or vertical mounting
Flexible earth lead
Pedestal (insulated or not)

 
 

Disconnecting device S3D2 type

 
 

The disconnecting device (S3D2) separates
automatically the bottom terminal of the failed
arrester from earth
It provides a visual indication of the failure
It gives priority to continuity of service
The disconnector is not a fault clearing device

 
 
 
 
 
 
 

View More  

Not exactly what you want?

Post Sourcing Request

Hot Searches

Lightning
Power Surge
Surge Protection
Surge Protector
Surge Arrester
Power Surge Protection
View More 

We are China Lug, Alum. 2 Hole Canton 394.5mcm manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular jgtrade1 Products

Gw9 -12/Series Hv Outdoor High Voltage Disconnect /Switch Isolator Disconnect Switch / Isolation

Splice Compression Sleeve Preinsulated No. 4/0 to 4/0 AWG

Distribution Arrester

U-Shaped Conductor Twisted 90 Degrees

Polymer Fuse Cutout, Drop out Fuses 27 Kv 200A

Polymer Fuse Cutout, Drop out Fuses 27kv 100A

Popular Lightning Arrester Products

33kv Composite Surge Arrester Lightning Arrester Metal Oxide Gapless Polymer Synthetic Polymeric 15kv 22kv 33kv 36kv High Voltage Porcelain Ceramic Station

24kv Polymer ZnO Lightning Arrester

Rated Voltage 132kv Rated Current 10ka Station Class Gapless Surge Diverter

Kema Tested High Voltage ZnO Surge Arresters with Factory Price

Metal-Oxide Lightning Arrester, Surge Arrester Yh5w, Yh10W

33kv Porcelain Type Surge Arrester Y10W-33

Popular Lightning Arrestors Products

Y10W-66, 66kv 10ka Surge Arrester

15kv Porcelain Lightning Arrester Bushing

27kv Polymer Surge Arresters

Yh10W-9, Sharp Head 10kv 9ka Surge Arrester

Factory Directly Sell Hy5wz-17/45 Metal Oxide Lightning Arrester Fyk Station Type for High Voltage Cabinet, Switchgear

Composite Surge Lighting Arrester Manufacturer

Popular Surge Arrester Products

Insulator Ladder

Included Disconnector Bracket Composite Arrestor 10ka, 36kv for Substation

Pin, Cross Arm 1"

9kv High Voltage Surge Arrester for Distribution Line

Double Straps Type P

Polymer Housed Metal Oxide Surge Arrester Without Gaps

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION