Outdoor Substation Rated Voltage 21kv 5ka 10ka Station Class Surge Arrestor
Outdoor Substation Rated Voltage 21kv 5ka 10ka Station Class Surge Arrestor image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
Type | YH5W5-21/56 | 4/10µS High current impulse kA | 65 |
Rated voltage———kV | 21 | Lightning impulse withstand kV | 125 |
MCOV —————-kV | 17 | Power frequency voltage withstand(dry/wet)kV | 50 |
Nominal Current——-kV | 5 | 0.1S TOV————–kV | 25.2 |
Residual voltage of steep impulse—-at 5kA(kV) | 60.5 | 1S TOV—————-kV | 24.15 |
8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 56 | 10S TOV—————kV | 23.1 |
Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | / | 1200S TOV————-kV | 21 |
1mA D.C reference voltage (kV) | 29.7 | Creepage distance —-mm | 662 |
Line discharge level | 1 | Material employed in series non-linear resistor | Zinc Oxide |
2mS long duration impulse current A | 250 | Material of housing | silicone rubber |
Working condition:
Environment temperature: -40–+40 degree | |||||||
altitude:<1000m | |||||||
48HZ<Rated frequency<62HZ | |||||||
Power frequency voltage should not be more than continuous running voltage | |||||||
Max wind speed should be less than 35m/s | |||||||
Earthquake intensity should be less than 7 degree | |||||||
If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Outdoor Substation Rated Voltage 21kv 5ka 10ka Station Class Surge Arrestor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
D85 Metal Oxide Varistor for Surge Arrester
Metal Oxide Lightening Arrestor for Surge Protector
15kv 66kv Antenna Surge Arrester Lightning Arrester Tester
12 Kv Silicon Rubber Housed Lighting Arrest Surge Lightning Arrester
Kema Type Test Report Rated Voltage 18kv Zinc Oxide Lighting Arrester
D35 Varistor for Surge Arrester
Popular Lightning Arrester Products
6kv Silicon Type Surge Arrester Cmr5w-11
Hy1.5W-0.28/1.3 Zinc-Oxide Arrester
Pararrayo Polymer of Distribution 10 Kv
11kv Porcelain Type Surge Arrester Y10c-11-1
36kv Porcelain Type Surge Arrester Y10c-36-1
Y10W-66, 66kv 10ka Surge Arrester
Popular Surge Arrester Products
Factory Supply 24kv 33kv 36kv Silicon Rubber Lightning Arresters
9kv Metal-Oxide Surge Arrester for Overvoltage Protection
132kv Hv Silicon Rubber Surge Arresters in Hangzhou
Polymer Housed Metal Oxide Surge Arrester
3kv~220kv Surge Arrester Lighting Arrester
Single Flexible Bus-Bar Supports Type Mdg
Popular Surge Arresters Products
33kv 10ka High Quality Silicone Housed Gapless Surge Diverters
5ka (3-36KV) Polymeric Housed Zinc Oxide Lightning Arresters Without Gaps
33kv Hv Polymeric Housed Silicone ZnO Gapless Lightning Arrestor
Mv Composite Metal Oxide Surge Arrester Without Gaps
Polymeric Housed Zinc Oxide Lightning Surge Arresters Series Surge Protector
Kema Lighting Arrest Surge Lightning Arrester for Substation
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters