Rated Voltage 110kv Mcov 86kv Porcelain Ceramic Housed Lightning Arrestor
Rated Voltage 110kv Mcov 86kv Porcelain Ceramic Housed Lightning Arrestor image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
Type: |
Y5W5-108/259 |
||
Rated voltage———kV | 108 | 4/10µS High current impulse kA | 100 |
MCOV —————-kV | 86 | Lightning impulse withstand kV | 550 |
Nominal Current——-kA | 5 | Power frequency voltage withstand(dry/wet)kV | 230 |
Residual voltage of steep impulse—-at 5kA(kV) | 339 | 0.1S TOV————–kV | 129.6 |
8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 281 | 1S TOV—————-kV | 124.2 |
Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 220 | 10S TOV—————kV | 118.8 |
1mA D.C reference voltage (kV) | 157 | 1200S TOV————-kV | 108 |
Line discharge level | 2 | Creepage distance —-mm | 3906 |
2mS long duration impulse current A | 600 | Material employed in series non-linear resistor | Zinc Oxide |
Working condition:
Environment temperature: -40–+40 degree | |||||||
altitude:<1000m | |||||||
48HZ<Rated frequency<62HZ | |||||||
Power frequency voltage should not be more than continuous running voltage | |||||||
Max wind speed should be less than 35m/s | |||||||
Earthquake intensity should be less than 7 degree | |||||||
If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Rated Voltage 110kv Mcov 86kv Porcelain Ceramic Housed Lightning Arrestor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Lightning Protection Surge Protection Device Arrester
132kv Transmission Line Type 24kv 10ka Lightning Arrester Without Gap
Types of Resistors Vdr Metal Oxide Varistor Used
High Quality Type of Lighting Arrestors
China High Quality Outdoor Substation Medium Voltage Disconnector Switch
Hangzhou Fuyang Lighting Arrest Surge Arresters 10kv
Popular Lightning Arrester Products
Insulator, Rack / Spool 53 - 2 C909-1032
66kv Ceramic Porcelain Housing Lightning Surge Arrester
Polymer Fuse Cutout, Drop out Fuses 25kv 200A
33kv Porcelain Type Surge Arrester Y10W-33
Yh10W-9, Sharp Head 10kv 9ka Surge Arrester 001
33kv Composite Surge Arrester Lightning Arrester Metal Oxide Gapless Polymer Synthetic Polymeric
Popular Surge Arrester Products
Polymeric Material Surge Arrester for 24kv/100A
Power Equipment 6-9kv Electrical Surge Arrester Low Voltage
Low Voltage Polymeric Moa ZnO Lightning Surge Arrester 6kv
High Voltage 24kv Porcelain ZnO Surge Arrester
Popular Surge Arresters Products
3-36kv Polymeric Lightning Arresters/Surge Arrester with Gap &Gap-Less Polymer Housed
10ka Power Station Type Ceramic ZnO Surge Diverters with Silicone Housed
Polymeric Housed Zinc Oxide Lightning Arresters Without Gaps
Outdoor Station Type 11kv-220kv Polymeric Lightning Arrester (type test)
24kv 10ka Polymer Housed Surge Arrester
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters