TECHNICAL SPECIFICATION
 
                                                               D Bracket
PART 1     GENERAL
 
1.01      SCOPE
This Specification covers the design, manufacturing, testing supply, delivery and performance requirements of D Bracket for use on overhead networks.
1.02      STANDARDS
The fittings comply with the latest editions of, and amendments to, the standards listed below:
 
BS                                                    –     British Standards Institution
 
BS 3288                                    –     Insulator and Conductor Fittings for Overhead Power Lines
 
BS EN ISO 1461                 –  Hot Dip Galvanized Coatings on Iron and Steel Articles
 
VDE                                                 –     Verband Deutscher Elecktrotechniker
    
 
VDE 0202                                 –     Requirements for aluminum for Electrical Technology 
 
DIN                                              –     Deutsche Industrie Normen
 
DIN 6796                                  –     Conic spring Washers
 
1.03    SERVICE CONDITIONS
 
Suitable for outdoor use in the Tropical zone,with a maximum ambient temperature of approximately 30degrees centigrade with heavy rainfall and high humidity of approximately 100% .
1.04    SYSTEM CONDITIONS
Comply the Customer requirment.
1.05    TESTING
A.       Routine Tests
1.        Routine tests carried out on all units of a particular type.
 
2.        Mechanical routine testing will be carried out in accordance with BS 3288; Part 1.
 
3.        The results of these tests will be recorded on a Routine Test Certificate.
 
4.        Routine Test Certificates will include, in addition to the test results, the Purchaser’s Order Number.
 
B.       Type Tests
1.        Type tests will be carried out on individual units of a particular type.
2.        Type tests will be in accordance with BS 3288: Part 1.
C.       Sample Tests
1.        Method of sampling and testing and test parameters shall be in accordance with BS 3288: Part 1.
2.        Test results shall be recorded in the same manner as routine tests.
D.       Inspection
 
The Purchaser reserves the right to witness the manufacturing process, any type tests specifically performed on the insulators to be supplied to ECG and any routine tests required in the manufacture and supply of the insulators and fittings. The Supplier shall provide free access to the Purchaser to any site where such manufacturing process, or tests, either type or routine tests are taking place.  The Supplier shall bear the in plant costs of such inspection.  The Supplier shall provide the Purchaser of a schedule of manufacture and tests at least two weeks before the events are to occur.
1.06      SPARES
(Not Applicable)
1.07      PACKING AND SHIPMENT
Export Standard
1.08      SUBMITTAL
As specified Of Customer
PART 2          PRODUCTS        
2.01    DESIGN
According to the Drawing Attach

View More  

Not exactly what you want?

Post Sourcing Request

Hot Searches

Pole
High Voltage Electric
Ac High Voltage
High Voltage Motor
High Voltage Power Supply
High Voltage Switch
View More 

We are China Convex Support manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular D bracket Products

D Iron D Bracket D Clevis D Shackle with Cotter Pin U Shackle U Clevis

D Iron/Secondary Rack Swinging Clevis Bracket for Insulator

HDG Steel D Iron D Bracket D Clevis D Type Shackle with Cotter Pin U Shackle U Clevis

Dt, Dt Copper Auminium Connecting Terminal

HDG D Iron D Bracket D Clevis D Type Shackle with Cotter Pin U Shackle U Clevis

Dgl Pole Top Rain Cap

Popular High Voltage Fuse Products

10 Gauge Knitted Glovescotton/Polyesterunbleached/Bleached White 7-11

Polyester Lined Glove Coated with PU (black)

RW11 Series 12kv 100/200A Outdoor High Voltage Protection Switch Drop-out Fuse

Hrw12-24 Composite Cutout Fuse Used

11kv 3A Expulsion Fuse Link

Xrnm 6kv 12kv 50ka Best Selling High Voltage Current Limiting Fuses for Motor Protection British BS Standards

Popular jgtrade1 Products

Hard Drawn Copper and Aluminium Conductors

Sleeve, Pre-Insul. Service No. Es 2W2w

Insulating Baffle

V Type D Fuse 11kv

Insulator, Pintype 55 - 5 1" C905-1305

Chave Fusivel Porcelana

Popular Pole Line Hardware Products

Hot DIP Galvanized Preformed Thimble Deadend Clevis

Galvanized Ut Clamp for Pole Line Hardware

Clevis Tongue for Pole Line Hardware

M16*`1800mm with Plate Stay Rod Ground Anchor as Pole Line Hardware

Suspension Staple Aluminum Scale 0.198"-0.732" Grapa De Suspension

Secondary Swinging Clevis/D Iron Bracket for Spool Type Insulators

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION