6kv High Quality Oxide Zinc Lightning Arrester for Substation
6kv High Quality Oxide Zinc Lightning Arrester for Substation image
Get Latest Price Request a quote
Basic Info.
Product Description
Surge Arrester Series
General
1. Ratings:0.22~500KV (porcelain),0.22~220KV(composite)
2. Application:for protection of power transmission & distribution system from over-voltage.
3. Features:
1)Silicone polymer housing composite metal oxide surge arrester and porcelain housing metal Oxide surge arresters are available.
2)Easy installation and maintenance.
3)Good sealing capability to ensure reliable operation.
4)Protection and reliability of the surge arrester have been greatly enhanced.
Working Condition
1. Ambient air temperature:-40ºC ~+40ºC ;
2. Altitude:<=2000m;
3. Frequency: 48Hz~62Hz;
4. Power frequency voltage applied between terminals of surge arrester must not exceed continuous operating voltage of surge arrerter;
5. Earthquake intensity is less than 8 degree;
6. Max. Wind speed is 35m/s.
Main Techical Parameter
1. Metal oxide Polymer Housing (Gapless) type Surge Arrester for A.C System(5kA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| YH-5W-6 | 6 | 5.1 | 18 | 320 | 150 | 65 | |
| YH-5W-9 | 9 | 7.65 | 27 | 430 | 150 | 65 | |
| YH-5W-12 | 12 | 10.2 | 36 | 430 | 150 | 65 | |
| YH-5W-15 | 15 | 12.75 | 45 | 530 | 150 | 65 | |
| YH-5W-18 | 18 |
15.3 |
54 | 530 | 150 | 65 | |
| YH-5W-21 | 21 | 16.8 | 63 | 640 | 150 | 65 | |
| YH-5W-24 | 24 | 19.2 | 72 | 640 | 150 | 65 | |
| YH-5W-27 | 27 | 21.6 | 81 | 740 | 150 | 65 | |
| YH-5W-30 | 30 | 24 | 90 | 890 | 150 | 65 | |
| YH-5W-33 | 33 | 26.4 | 99 | 890 | 150 | 65 | |
| YH-5W-36 | 36 | 28.8 | 108 | 1115 | 150 | 65 |
2. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (10KA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| YH-10W-6 | 6 | 5.1 | 18 | 1 | 320 | 250 | 100 |
| YH-10W-9 | 9 | 7.65 | 27 | 1 | 430 | 250 | 100 |
| YH-10W-12 | 12 | 10.2 | 36 | 1 | 430 | 250 | 100 |
| YH-10W-15 | 15 | 12.75 | 45 | 1 | 530 | 250 | 100 |
| YH-10W-18 | 18 | 15.3 | 54 | 1 | 530 | 250 | 100 |
| YH-10W-21 | 21 | 16.8 | 63 | 1 | 640 | 250 | 100 |
| YH-10W-24 | 24 | 19.2 | 72 | 1 | 740 | 250 | 100 |
| YH-10W-27 | 27 | 21.6 | 81 | 1 | 740 | 250 | 100 |
| YH-10W-30 | 30 | 24 | 90 | 1 | 890 | 250 | 100 |
| YH-10W-33 | 33 | 26.4 | 99 | 1 | 890 | 250 | 100 |
| YH-10W-36 | 36 | 28.8 | 108 | 1 | 1115 | 250 | 100 |
| YH-10W-42 | 42 | 33.6 | 126 | 2 | 1260 | 400 | 100 |
| YH-10W-48 | 48 | 39 | 139 | 2 | 1260 | 400 | 100 |
| YH-10W-54 | 54 | 42 | 160 | 2 | 1260 | 400 | 100 |
| YH-10W-60 | 60 | 48 | 178 | 2 | 1465 | 400 | 100 |
| YH-10W-66 | 66 | 52.8 | 196 | 2 | 1465 | 400 | 100 |
| YH-10W-72 | 72 | 57 | 214 | 2 | 2255 | 400 | 100 |
| YH-10W-84 | 84 | 67.2 | 244 | 2 | 2255 | 400 | 100 |
| YH-10W-90 | 90 | 72.5 | 249 | 2 | 2255 | 400 | 100 |
| YH-10W-96 | 96 | 75 | 265 | 3 | 3555 | 800 | 100 |
| YH-10W-108 | 108 | 84 | 281 | 3 | 3555 | 800 | 100 |
| YH-10W-120 | 120 | 96 | 300 | 3 | 4153 | 800 | 100 |
| YH-10W-150 | 150 | 120 | 416 | 3 | 5040 | 800 | 100 |
| YH-10W-200 | 200 | 156 | 520 | 3 | 7110 | 800 | 100 |
3. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (20KA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| YH-20W-108 | 108 | 84 | 281 | 3 | 3555 | 800 | 100 |
| YH-20W-120 | 120 | 96 | 300 | 3 | 4153 | 800 | 100 |
| YH-20W-150 | 150 | 120 | 416 | 3 | 5040 | 800 | 100 |
| YH-20W-200 | 200 | 156 | 520 | 3 | 7110 | 800 | 100 |
4. Metal Oxide Porcelain Housing (Gapless) type Surge Arrester for A.C. System (5KA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| Y5W-6 | 6 | 5.1 | 18 | 280 | 150 | 65 | |
| Y5W-9 | 9 | 7.65 | 27 | 320 | 150 | 65 | |
| Y5W-12 | 12 | 10.2 | 36 | 320 | 150 | 65 | |
| Y5W-15 | 15 | 12.75 | 45 | 450 | 150 | 65 | |
| Y5W-18 | 18 |
15.3 |
54 | 450 | 150 | 65 | |
| Y5W-21 | 21 | 16.8 | 63 | 450 | 150 | 65 | |
| Y5W-24 | 24 | 19.2 | 72 | 510 | 150 | 65 | |
| Y5W-27 | 27 | 21.6 | 81 | 510 | 150 | 65 | |
| Y5W-30 | 30 | 24 | 90 | 890 | 150 | 65 | |
| Y5W-33 | 33 | 26.4 | 99 | 890 | 150 | 65 | |
| Y5W-36 | 36 | 28.8 | 108 | 890 | 150 | 65 |
5. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (10KA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| Y10W-6 | 6 | 5.1 | 18 | 1 | 280 | 250 | 100 |
| Y10W-9 | 9 | 7.65 | 27 | 1 | 320 | 250 | 100 |
| Y10W-12 | 12 | 10.2 | 36 | 1 | 320 | 250 | 100 |
| Y10W-15 | 15 | 12.75 | 45 | 1 | 450 | 250 | 100 |
| Y10W-18 | 18 | 15.3 | 54 | 1 | 450 | 250 | 100 |
| Y10W-21 | 21 | 16.8 | 63 | 1 | 450 | 250 | 100 |
| Y10W-24 | 24 | 19.2 | 72 | 1 | 510 | 250 | 100 |
| Y10W-27 | 27 | 21.6 | 81 | 1 | 510 | 250 | 100 |
| Y10W-30 | 30 | 24 | 90 | 1 | 890 | 250 | 100 |
| Y10W-33 | 33 | 26.4 | 99 | 1 | 890 | 250 | 100 |
| Y10W-36 | 36 | 28.8 | 108 | 1 | 890 | 250 | 100 |
| Y10W-42 | 42 | 33.6 | 126 | 2 | 1256 | 400 | 100 |
| Y10W-48 | 48 | 39 | 139 | 2 | 1256 | 400 | 100 |
| Y10W-54 | 54 | 42 | 160 | 2 | 1256 | 400 | 100 |
| Y10W-60 | 60 | 48 | 178 | 2 | 1440 | 400 | 100 |
| Y10W-66 | 66 | 52.8 | 196 | 2 | 1440 | 400 | 100 |
| Y10W-72 | 72 | 57 | 214 | 2 | 1440 | 400 | 100 |
| Y10W-84 | 84 | 67.2 | 244 | 2 | 2200 | 400 | 100 |
| Y10W-90 | 90 | 72.5 | 249 | 2 | 2200 | 400 | 100 |
| Y10W-96 | 96 | 75 | 265 | 3 | 3350 | 800 | 100 |
| Y10W-108 | 108 | 84 | 281 | 3 | 3350 | 800 | 100 |
| Y10W-120 | 120 | 96 | 300 | 3 | 3948 | 800 | 100 |
| Y10W-150 | 150 | 120 | 416 | 3 | 4400 | 800 | 100 |
| Y10W-200 | 200 | 156 | 520 | 3 | 6700 | 800 | 100 |
6. Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (20KA series)
| Model | Rated voltage (kVr.m.s) | Continuous operating Voltage(KVr.m.s) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Line discharge class | Creepage distance(mm) | 2ms square wave impulse current withstands(A) | 4/10μhigh current impulse Withstands(KAp) |
| Y20W-108 | 108 | 84 | 281 | 3 | 3555 | 800 | 100 |
| Y20W-120 | 120 | 96 | 300 | 3 | 4106 | 800 | 100 |
| Y20W-150 | 150 | 120 | 416 | 3 | 4400 | 800 | 100 |
| Y20W-200 | 200 | 156 | 520 | 3 | 6700 | 800 | 100 |
| Y20W-444 | 444 | 324 | 1106 | 4 | 17052 | 2000 | 100 |
Note: For details, please refer to the catalogue.
Participate in the exhibition pictures
testing report
We are China 6kv High Quality Oxide Zinc Lightning Arrester for Substation manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular High Quality Oxide Zinc Lightning Arrester Products
9kv High Quality Oxide Zinc Lightning Arrester for Substation
24kv High Quality Oxide Zinc Lightning Arrester for Substation
36kv High Quality Oxide Zinc Lightning Arrester for Substation
15kv High Quality Oxide Zinc Lightning Arrester for Substation
27kv High Quality Oxide Zinc Lightning Arrester for Substation
33kv High Quality Oxide Zinc Lightning Arrester for Substation
Popular Lightning Arrester Products
Metal-Oxide Surge Arrester Lighting Arrester
200kv Metal Oxide Lightning Arrester for Overvoltage Protection
Class1 Line Discharge Level 21kv 5ka Polymeric Composite Lighting Arrester
66kv Silicon Type Surge Arrester Cma5wx96/250
11kv Porcelain Type Surge Arrester Y10c-11
Popular Oxide Zinc Lightning Arrester for Substation Products
21kv High Quality Oxide Zinc Lightning Arrester for Substation
36kv High Quality Oxide Zinc Lightning Arrester for Substation
30kv High Quality Oxide Zinc Lightning Arrester for Substation
18kv High Quality Oxide Zinc Lightning Arrester for Substation
27kv High Quality Oxide Zinc Lightning Arrester for Substation
12kv High Quality Oxide Zinc Lightning Arrester for Substation
Popular people Products
Hot DIP Galvanization Pigtail Bolt for Overhead Line
Strain Porcelain Insulators for Lines (ANSI)
Outdoor Expulsion Drop-out Type Distribution Fuse Cutout Series
Long Rod Suspension Composite Insulator
36kv Ceramic High Quality Drop out Fuse Cutout
15kv Outdoor Expulsion Drop-out Type Loadbreak Fuse Cutout
Tags: High Quality Oxide Zinc Lightning Arrester, Lightning Arrester, Oxide Zinc Lightning Arrester for Substation, people