High Voltage Ceramic Zinc Oxide Surge Arrester
High Voltage Ceramic Zinc Oxide Surge Arrester image
Get Latest Price Request a quote
Quick Details
Product Details
Main features:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
| Type | Y10W5-66/176 |
| Rated voltage———kV | 66 |
| MCOV —————-kV | 52.8 |
| Nominal Current——-kA | 10 |
| Residual voltage of steep impulse—-at 5kA(kV) | 221 |
| 8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 178 |
| Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 137 |
| 1mA D.C reference voltage (kV) | 96 |
| Line discharge level | 1 |
| 2mS long duration impulse current A | 400 |
| 4/10µS High current impulse kA | 100 |
| Lightning impulse withstand kV | 325 |
| Power frequency voltage withstand(dry/wet)kV | 140 |
| 0.1S TOV————–kV | 79.2 |
| 1S TOV—————-kV | 75.9 |
| 10S TOV—————kV | 72.6 |
| 1200S TOV————-kV | 66 |
| Creepage distance —-mm | 2500 |
| Material employed in series non-linear resistor | Zinc Oxide |
Working condition:
| Environment temperature: -40–+40 degree | |||||||
| altitude:<1000m | |||||||
| 48HZ<Rated frequency<62HZ | |||||||
| Power frequency voltage should not be more than continuous running voltage | |||||||
| Max wind speed should be less than 35m/s | |||||||
| Earthquake intensity should be less than 7 degree | |||||||
| If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China High Voltage Ceramic Zinc Oxide Surge Arrester manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Low Voltage 12kv Metal Oxide Surge Arrester with Kema
Fuyang SMD Resistor Voltage Dependent Resistor/ Zinc Oxide Nonlinear Varistor
Polymeric Zinc Oxide Surge Arrester 24kv 5ka for Electrical Substation
Composite Housing Surge Arrester 5ka, 12kv
Medium Voltage Isolator Switch Fuse Disconnector
Manufacturer 15kv Surge Protector Zinc Oxide Lightning Arrester for Transformers
Popular Lightning Arrester Products
33kv Porcelain Type Surge Arrester Y10c-33
High Voltage Line Type ZnO Lightning Arrestors Yh10W-15
Hy5wz-7.6/27 Zinc-Oxide Arrester
Yh10W-42, Sharp Head 42kv 20ka Surge Arrester
15kv Polymeric Housed Metal-Oxide Lightning Arrester Without Gaps
Popular Surge Arrester Products
33kv LV Zinc Oxide Surge Arrester
27kv Metal-Oxide Surge Arrester for Overvoltage Protection
11kv Porcelain Type Surge Arrester Y10W-11
View Larger Image11kv Silicone Rubber Lightning Arrester
Silicone Rubber Energy-Saving Low Voltage Arrester
3kv Silicon Rubber Lightning Arrester
Popular Surge Arresters Products
Power Protection and Control Devices, Surge Arresters
30kv/10ka Metal-Oxide Polymeric Surge Arrester
Lightning Arrestor High Voltage Metal Oxide Station Surge Arrestor
Line Discharge Level 1 Porcelain Arrester Lightening Arrester with External Gap
High Voltage Composite/ Ceramic Housed Lightning Arrester 15kv
High Voltage Disconnector for Surge Arrester
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters