Rated Voltage 110kv Mcov 86kv Porcelain Ceramic Housed Lightning Arrestor
Rated Voltage 110kv Mcov 86kv Porcelain Ceramic Housed Lightning Arrestor image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
Type: |
Y5W5-108/259 |
||
Rated voltage———kV | 108 | 4/10µS High current impulse kA | 100 |
MCOV —————-kV | 86 | Lightning impulse withstand kV | 550 |
Nominal Current——-kA | 5 | Power frequency voltage withstand(dry/wet)kV | 230 |
Residual voltage of steep impulse—-at 5kA(kV) | 339 | 0.1S TOV————–kV | 129.6 |
8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 281 | 1S TOV—————-kV | 124.2 |
Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 220 | 10S TOV—————kV | 118.8 |
1mA D.C reference voltage (kV) | 157 | 1200S TOV————-kV | 108 |
Line discharge level | 2 | Creepage distance —-mm | 3906 |
2mS long duration impulse current A | 600 | Material employed in series non-linear resistor | Zinc Oxide |
Working condition:
Environment temperature: -40–+40 degree | |||||||
altitude:<1000m | |||||||
48HZ<Rated frequency<62HZ | |||||||
Power frequency voltage should not be more than continuous running voltage | |||||||
Max wind speed should be less than 35m/s | |||||||
Earthquake intensity should be less than 7 degree | |||||||
If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Rated Voltage 110kv Mcov 86kv Porcelain Ceramic Housed Lightning Arrestor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Hangzhou Electrical Single Phase Isolator Switch Switchgear
Rated Voltage 132kv Rated Current 10ka Station Class Gapless Surge Diverter
Outdoor 3 Phase Isolating Switch of High Voltage
132kv Silicone ZnO Surge Protector for 500kv Transmission Lines
Metal Oxide Lightning Arrester (YH10W5-3)
24-27kv Polymer Housing Fuse Cutout
Popular Lightning Arrester Products
Polymer Fuse Cutout, Drop out Fuses 3kv 100A
Yh6w-24, 24kv 6ka Surge Arrester
Hy10W-12, 12kv 10ka Surge Arrester
63kv to 220kv Sealed Metal Oxide Surge Arrester for Gis
Popular Surge Arrester Products
Yh10W-60, Sharp Head 60kv 20ka Surge Arrester
54kv Polymeric Housed Metal Oxide Surge Arrester
10ka 36kv Polymer Housed Metal Oxide Surge Arrester Without Gaps
Lug, Alum. 2 Hole Canton 394.5mcm
66kv Substation Active Ceramic Porcelain Housing Lightning Surge Arrester
Silicon Rubber Housed Metal Oxide Gapless Surge Arrester with Type Test Report
Popular Surge Arresters Products
High Voltage Ceramic Zinc Oxide Surge Arrester
Class1 Line Discharge Level 21kv 5ka Polymeric Composite Lighting Arrester
High Voltage ZnO Types of Lightning Arrester with Cap
Polymer Housed Gapless Metal Oxide 66kv Power Surge Arrester
High Voltage Transmission Line Polymer Silicone Rubber Zinc-Oxide Lightning Arrestor
35kv-220kv Polymer Housed Zinc Oxide Surge Arrester
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters