Line Discharge Level 1 Porcelain Arrester Lightening Arrester with External Gap
Line Discharge Level 1 Porcelain Arrester Lightening Arrester with External Gap image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
Type | YH5W5-21/56 | 4/10µS High current impulse kA | 65 |
Rated voltage———kV | 21 | Lightning impulse withstand kV | 125 |
MCOV —————-kV | 17 | Power frequency voltage withstand(dry/wet)kV | 50 |
Nominal Current——-kV | 5 | 0.1S TOV————–kV | 25.2 |
Residual voltage of steep impulse—-at 5kA(kV) | 60.5 | 1S TOV—————-kV | 24.15 |
8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 56 | 10S TOV—————kV | 23.1 |
Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | / | 1200S TOV————-kV | 21 |
1mA D.C reference voltage (kV) | 29.7 | Creepage distance —-mm | 662 |
Line discharge level | 1 | Material employed in series non-linear resistor | Zinc Oxide |
2mS long duration impulse current A | 250 | Material of housing | silicone rubber |
Working condition:
Environment temperature: -40–+40 degree | |||||||
altitude:<1000m | |||||||
48HZ<Rated frequency<62HZ | |||||||
Power frequency voltage should not be more than continuous running voltage | |||||||
Max wind speed should be less than 35m/s | |||||||
Earthquake intensity should be less than 7 degree | |||||||
If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Line Discharge Level 1 Porcelain Arrester Lightening Arrester with External Gap manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Lighting Arrestor Surge Arrester Lightning Protector Surge Protector
Zink Oxide Varistor for Sruge Lighting Arrester
Power Equipment 6-9kv Electrical Surge Arrester Low Voltage
Easy Assembled 245kv 1250/4000A High Voltage Disconnect Isolator Switch
High Voltage Transmission Line Polymer Silicone Rubber Zinc-Oxide Lightning Arrestor
1mA D. C Reference Voltage 29.7kv Zinc-Oxide Lightening Arresters up to 500kv
Popular Lightning Arrester Products
Hangzhou Fuyang ZnO Polymeric Lightning Arrester Lightning Rod
Yh5w-30, 30kv 5ka Surge Arrester
Yh10W-42, 42kv 10ka Surge Arrester
Terminal Connectors for Double Conductors Bolted Type, Type Ssl, Group B
Popular Surge Arrester Products
36kv Porcelain Type Surge Arrester Y10W-36
Surge Protection SPD Surge Arrester
5kv~765kv Metal Oxide Gapless Surge Arrester for Transformer/Lightning Arrester
Single Flexible Bus-Bar Supports Type Mdg
Polymer Fuse Cutout, Drop out Fuses 3kv 100A
Popular Surge Arresters Products
Polymer Housed Metal Oxide Surge Arrester Without Gaps
High Voltage Disconnector for Surge Arrester
Lightning Arrestor High Voltage Metal Oxide Station Surge Arrestor
Metal Oxide Polymeric Lightning Arresters
33kv/10ka Polymeric Surge Arrester
Hangzhou Substation Type Rated Voltage 3-36kv Composite Housed Surge Protectors
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters