Outdoor Electric Line Discharge Level 1 to 5 Porcelain Lighting Arrester 110kv
Outdoor Electric Line Discharge Level 1 to 5 Porcelain Lighting Arrester 110kv image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
| Type | Y10W5-108/281 |
| Rated Voltage———kV | 108 |
| MCOV —————-kV | 86 |
| Nominal Current——-kA | 10 |
| Residual voltage of steep impulse—-at 5kA(kV) | 325 |
| 8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 274 |
| Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 215 |
| 1mA D.C reference voltage (kV) | 157 |
| Line discharge level | 3 |
| 2mS long duration impulse current A | 850 |
| 4/10µS High current impulse kA | 100 |
| Lightning impulse withstand kV | 550 |
| Power frequency voltage withstand(dry/wet)kV | 230 |
| 0.1S TOV————–kV | 129.6 |
| 1S TOV—————-kV | 124.2 |
| 10S TOV—————kV | 118.8 |
| 1200S TOV————-kV | 108 |
| Creepage distance —-mm | 3906 |
| Material employed in series non-linear resistor | Zinc Oxide |
Working condition:
| Environment temperature: -40–+40 degree | |||||||
| altitude:<1000m | |||||||
| 48HZ<Rated frequency<62HZ | |||||||
| Power frequency voltage should not be more than continuous running voltage | |||||||
| Max wind speed should be less than 35m/s | |||||||
| Earthquake intensity should be less than 7 degree | |||||||
| If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Outdoor Electric Line Discharge Level 1 to 5 Porcelain Lighting Arrester 110kv manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
High Quality Surge Protection Lightning Arrestor
Hv Porcelain Ceramic Gapless Zinc Oxide Lightning Surge Arresters
Low Cost 33-66kv Low Voltage Metal Oxide Surge Protective Device Arresters
Surge Arrester Silicon Rubber Insulator
Lightning Arrestors/Arrester Surge Protector Surge Arrester
Export 33kv Lightning Arrester Zinc Oxide Varistor
Popular Lightning Arrester Products
132kv Transmission Line Type 24kv 10ka Lightning Arrester Without Gap
Terminal Connectors for Double Conductors Bolted Type, Type Ssl, Group B
OEM Lighting Arrester Protective Device 36kv Composite Lightning Arrestor
High Voltage Lightning and Surge Arrester
Popular Surge Arrester Products
30kv High Voltage Surge Arrester for Distribution Line
Outdoor Class2 Hv Polymer Ceramic Porcelain Zinc Oxide Surge Arrester
Surge Protector Metal Oxide Zino Lightning Arrester
Wholesale Medium Voltage ZnO Polymeric Surge Arrester 11kv
Dongzhou Factory Lightning Arrester Yh10W-18kv-21kv Surge Arrester
Popular Surge Arresters Products
24kv 10ka Polymer Housed Zinc Oxide Surge Arrester
Kema Electrical Transformer Type Rated Voltage 15kv to 132kv Zinc-Oxide Surge Protector
60kv Metal-Oxide Polymer Class3 Station Type Lightning Surge Arrester
220KV Porcelain Housed Station Surge Arrester
Rated Current 5ka Polymeric Housed Station Class Surge Diverters with Counter
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters