Outdoor Substation Rated Voltage 21kv 5ka 10ka Station Class Surge Arrestor
Outdoor Substation Rated Voltage 21kv 5ka 10ka Station Class Surge Arrestor image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
| Type | YH5W5-21/56 | 4/10µS High current impulse kA | 65 |
| Rated voltage———kV | 21 | Lightning impulse withstand kV | 125 |
| MCOV —————-kV | 17 | Power frequency voltage withstand(dry/wet)kV | 50 |
| Nominal Current——-kV | 5 | 0.1S TOV————–kV | 25.2 |
| Residual voltage of steep impulse—-at 5kA(kV) | 60.5 | 1S TOV—————-kV | 24.15 |
| 8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 56 | 10S TOV—————kV | 23.1 |
| Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | / | 1200S TOV————-kV | 21 |
| 1mA D.C reference voltage (kV) | 29.7 | Creepage distance —-mm | 662 |
| Line discharge level | 1 | Material employed in series non-linear resistor | Zinc Oxide |
| 2mS long duration impulse current A | 250 | Material of housing | silicone rubber |
Working condition:
| Environment temperature: -40–+40 degree | |||||||
| altitude:<1000m | |||||||
| 48HZ<Rated frequency<62HZ | |||||||
| Power frequency voltage should not be more than continuous running voltage | |||||||
| Max wind speed should be less than 35m/s | |||||||
| Earthquake intensity should be less than 7 degree | |||||||
| If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Outdoor Substation Rated Voltage 21kv 5ka 10ka Station Class Surge Arrestor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
2016 New High Voltage Polymer Surge Arrestor
Line Use 96-120kv Ploymer Housing Moa Surge Arrestor with External Gap
High Quality Electrically Operated Mechanism for Disconnector
Zinc Oxide Resistor for Surge Arrester
Transmission Line Medium Voltage Compostie Insulator
Suspension Transmission Line Medium Voltage Compostie Insulator
Popular Lightning Arrester Products
Outdoor Single Pole Fused Recloser by-Pass Switches24kv 001
Load Break Switch Fuse Disconnector 45kv 200A
35kv Silicone Rubber Bushing ZnO Surge Arrester Protector
Metal Oxide Lightning Arrester (MOV) /Outdoor Substation
36kv Zinc Oxide Surge Arrester
Popular Surge Arrester Products
Flexible Ladder (including ladder head)
Hot Sell Gapless Zinc Oxide Lighting Arrester
Factory Supply 24kv 33kv 36kv Silicon Rubber Lightning Arresters
Thunder Arrester Polymeric Housed Gapless Lightning Arrestor up to 550kv
66kv Ceramic Porcelain Housing Lightning Surge Arrester
Popular Surge Arresters Products
3kv-36kv 10ka Polymer Housed Surge Arrester
Kema Lighting Arrest Surge Lightning Arrester for Substation
Ceramic Zinc Oxide Lighting Arresters for Power House
High Voltage Transmission Line Polymer Silicone Rubber Zinc-Oxide Lightning Arrestor
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters