Rated Voltage 60kv Line Type Polymer Housing Lightning Arrestor Without Gaps
Rated Voltage 60kv Line Type Polymer Housing Lightning Arrestor Without Gaps image
Get Latest Price Request a quote
Quick Details
Product Details
Main features:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
| Type | Y10W5-66/176 |
| Rated voltage———kV | 66 |
| MCOV —————-kV | 52.8 |
| Nominal Current——-kA | 10 |
| Residual voltage of steep impulse—-at 5kA(kV) | 221 |
| 8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 178 |
| Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 137 |
| 1mA D.C reference voltage (kV) | 96 |
| Line discharge level | 1 |
| 2mS long duration impulse current A | 400 |
| 4/10µS High current impulse kA | 100 |
| Lightning impulse withstand kV | 325 |
| Power frequency voltage withstand(dry/wet)kV | 140 |
| 0.1S TOV————–kV | 79.2 |
| 1S TOV—————-kV | 75.9 |
| 10S TOV—————kV | 72.6 |
| 1200S TOV————-kV | 66 |
| Creepage distance —-mm | 2500 |
| Material employed in series non-linear resistor | Zinc Oxide |
Working condition:
| Environment temperature: -40–+40 degree | |||||||
| altitude:<1000m | |||||||
| 48HZ<Rated frequency<62HZ | |||||||
| Power frequency voltage should not be more than continuous running voltage | |||||||
| Max wind speed should be less than 35m/s | |||||||
| Earthquake intensity should be less than 7 degree | |||||||
| If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Rated Voltage 60kv Line Type Polymer Housing Lightning Arrestor Without Gaps manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
OEM/ODM Power Distribution Equipment 110kv Lightning Arrester with Kema Report
Kema Tested 12kv-24kv Polymeric Lightning Arrester in Hangzhou Fuyang
Double Break Disconnector (GW38-40.5~252/630~4000)
Porcelain Housed Lighting Arrester for Power Station
Electrical Transformer Class 1 15kv Lightning Arrester Types Images
Electric Power Line Material 27kv/5ka/10ka Metal Oxide Silicone Surge Arrester
Popular Lightning Arrestor Products
Hangzhou Fuyang 220kv Electrical Supplies Polymeric Gapless Lightning Arrestor
Transformer Surge Protection Lightning Arrestor
OEM ISO9001 Outdoor 198kv Zinc Oxide Lighting Arrester with Grading Ring
15kv Medium Voltage Lightning Arrestor
OEM/ODM Yongde Class 4 Hv 500kv Power Plant Lightning Arrester
Kema All Types Class 1 to 5 High Voltage Ceramic Lightning Arrester 220kv
Popular Surge Arrester Products
Xirui Factory 9kv Silicone Rubber Surge Arrester with Zino Oxide Varistors
12kv/5ka Polymeric Metal Oxide Surge Arrester
Power Station/Line Type Lightning Arrestors Transformer Arrester 12kv to 33kv
33kv Composite Zinc Metal-Oxide Arrester Lightning Arrester
Aerial Bundled Conductor (ABC)
Popular Surge Arresters Products
Power Protection and Control Devices, Surge Arresters
3-36kv Polymeric Lightning Arresters/Surge Arrester with Gap &Gap-Less Polymer Housed
Surge Arrester 30kv 33kv 36kv Metal-Oxide Composite Lightning Surge Arrester
Rated Voltage 100kv 110kv 120kv Transmission Line Type ZnO Lightning Diverter
Outdoor Substation Rated Voltage 21kv 5ka 10ka Station Class Surge Arrestor
10ka/ 5ka Gapless Lighting Arrest 21kv Moa Surge Diverter
Tags: hzyddq, Lightning Arrestor, Surge Arrester, Surge Arresters