Wholesale High Quality Bare Copper Core PVC Insulated Electrical Wire and Cable Building Wire
Wholesale High Quality Bare Copper Core PVC Insulated Electrical Wire and Cable Building Wire image
Get Latest Price Request a quote
Quick Details
Product Details
Application
A. It can be applied to be installation and connection for electrical device, equipment power device, domestic appliance, instrument,lighting circuit, and automation device.
B. The feature of flame retardant cable is not easy to be fired and can control the flame into certain restriction and slow the fire speed after fire. So it can be applied to the occasion with high request of flame retardant.
C. Flame cable can be divided into 4 grade: A,B,C,D and the Grade A is the best flame retardant grade.
D. Beside the cable can transfer power at the normal condition, it can also keep a period of safe operation under fire. It can be applied for the occasion with request of fire resistance.
Pruduct Structure
Reference Data of the Product Structure: IEC 60227
1. 01(BV)Cable
Nominal Section of the conductor (mm2) |
Conductor Types | Cable Reference Diameter (mm) |
Cable Average Diameter (mm) |
Cable Reference Weight (kg/km) |
Maximum Resistance of the conductor at 20ºC (/km) |
Minumum Insulation Resistance at 70ºC (M·km) |
Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
|
BV | Minimum | Maximum | BV | |||||
1.5 | 1 | 2.82 | 2.6 | 3.2 | 19.70 | 12.1 | 0.011 | 18 |
1.5 | 2 | 3.00 | 2.7 | 3.3 | 20.31 | 12.1 | 0.010 | 18 |
2.5 | 1 | 3.43 | 3.2 | 3.9 | 31.20 | 7.41 | 0.010 | 25 |
2.5 | 2 | 3.69 | 3.3 | 4.0 | 32.82 | 7.41 | 0.009 | 25 |
4 | 1 | 3.90 | 3.6 | 4.4 | 46.08 | 4.61 | 0.0085 | 33 |
4 | 2 | 4.20 | 3.8 | 4.6 | 47.45 | 4.61 | 0.0077 | 33 |
6 | 1 | 4.41 | 4.1 | 5.0 | 65.71 | 3.08 | 0.0070 | 42 |
6 | 2 | 4.77 | 4.3 | 5.2 | 67.19 | 3.08 | 0.0065 | 42 |
10 | 1 | 5.65 | 5.3 | 6.4 | 109.09 | 1.83 | 0.0070 | 58 |
10 | 2 | 6.13 | 5.6 | 6.7 | 113.07 | 1.83 | 0.0065 | 58 |
16 | 2 | 7.18 | 6.4 | 7.8 | 170.90 | 1.15 | 0.0050 | 78 |
25 | 2 | 8.92 | 8.1 | 9.7 | 268.52 | 0.727 | 0.0050 | 105 |
35 | 2 | 10.06 | 9.0 | 10.9 | 362.82 | 0.524 | 0.0043 | 130 |
50 | 2 | 11.81 | 10.6 | 12.8 | 492.15 | 0.387 | 0.0043 | 155 |
70 | 2 | 13.61 | 12.1 | 14.6 | 694.19 | 0.268 | 0.0035 | 200 |
95 | 2 | 15.93 | 14.1 | 17.1 | 959.23 | 0.193 | 0.0035 | 250 |
120 | 2 | 17.54 | 15.6 | 18.8 | 1197.15 | 0.153 | 0.0032 | 290 |
150 | 2 | 19.49 | 17.3 | 20.9 | 1472.95 | 0.124 | 0.0032 | 335 |
185 | 2 | 21.80 | 19.3 | 23.3 | 1846.14 | 0.0991 | 0.0032 | 390 |
240 | 2 | 24.83 | 22.0 | 26.6 | 2416.54 | 0.0754 | 0.0032 | 470 |
300 | 2 | 27.67 | 24.5 | 29.6 | 3023.55 | 0.0601 | 0.0030 | 540 |
400 | 2 | 31.06 | 27.5 | 33.2 | 3851.72 | 0.0470 | 0.0028 | 635 |
2.02(RV)Cable
Nominal Section of the conductor (mm2) |
Conductor Types | Cable Reference Diameter (mm) |
Cable Average Diameter (mm) |
Cable Reference Weight (kg/km) |
Maximum Resistance of the conductor at 20ºC (Ω/km) |
Minumum Insulation Resistance at 70ºC (MΩ·km) |
Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
|
RV | Minimum | Maximum | RV | |||||
1.5 | 5 | 3.00 | 2.8 | 3.4 | 20.30 | 13.3 | 0.010 | 18 |
2.5 | 5 | 3.64 | 3.4 | 4.1 | 31.59 | 7.98 | 0.009 | 25 |
4 | 5 | 4.21 | 3.9 | 4.8 | 47.54 | 4.95 | 0.0070 | 33 |
6 | 5 | 4.81 | 4.4 | 5.3 | 67.42 | 3.3 | 0.0060 | 42 |
10 | 5 | 6.28 | 5.7 | 6.8 | 118.00 | 1.81 | 0.0056 | 58 |
16 | 5 | 7.20 | 6.7 | 8.1 | 169.44 | 1.21 | 0.0046 | 78 |
25 | 5 | 10.10 | 8.4 | 10.2 | 269.71 | 0.78 | 0.0044 | 105 |
35 | 5 | 11.23 | 9.7 | 11.7 | 364.35 | 0.554 | 0.0038 | 130 |
50 | 5 | 13.75 | 11.5 | 13.9 | 522.86 | 0.386 | 0.0037 | 155 |
70 | 5 | 15.40 | 13.2 | 16.0 | 720.89 | 0.272 | 0.0032 | 200 |
95 | 5 | 18.15 | 15.1 | 18.2 | 953.89 | 0.206 | 0.0032 | 250 |
120 | 5 | 19.70 | 16.7 | 20.2 | 1199.28 | 0.161 | 0.0029 | 290 |
150 | 5 | 21.10 | 18.6 | 22.5 | 1485.62 | 0.129 | 0.0029 | 335 |
185 | 5 | 24.03 | 20.6 | 24.9 | 1824.52 | 0.106 | 0.0029 | 390 |
240 | 5 | 26.70 | 23.5 | 28.4 | 2389.69 | 0.0801 | 0.0028 | 470 |
3.05(BV)Cable
Nominal Section of the conductor (mm2) |
Conductor Types | Cable Reference Diameter (mm) |
Cable Average Diameter (mm) |
Cable Reference Weight (kg/km) |
Maximum Resistance of the conductor at 20ºC (Ω/km) |
Minumum Insulation Resistance at 70ºC (MΩ·km) |
Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
|
BV | Minimum | Maximum | BV | |||||
0.5 | 1 | 2.04 | 1.9 | 2.3 | 8.16 | 36.0 | 0.015 | 9 |
0.75 | 1 | 2.21 | 2.1 | 2.5 | 10.71 | 24.5 | 0.012 | 12 |
1 | 1 | 2.37 | 2.2 | 2.7 | 13.48 | 18.1 | 0.011 | 14 |
4.06(RV)Cable
Nominal Section of the conductor (mm2) |
Conductor Types | Cable Reference Diameter (mm) |
Cable Average Diameter (mm) |
Cable Reference Weight (kg/km) |
Maximum Resistance of the conductor at 20ºC (Ω/km) |
Minumum Insulation Resistance at 70ºC (MΩ·km) |
Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
|
RV | Minimum | Maximum | RV | |||||
0.5 | 5 | 2.18 | 2.1 | 2.5 | 8.58 | 39.0 | 0.013 | 9 |
0.75 | 5 | 2.43 | 2.2 | 2.7 | 11.50 | 26.0 | 0.011 | 12 |
1 | 5 | 2.52 | 2.4 | 2.8 | 14.00 | 19.5 | 0.010 | 14 |
5.10(BVV)Cable
Core No.×Nominal Section of the conductor (mm2) |
Conductor Types | Cable Reference Diameter (mm) |
Cable Average Diameter (mm) |
Cable Reference Weight (kg/km) |
Maximum Resistance of the conductor at 20ºC (Ω/km) |
Minumum Insulation Resistance at 70ºC (MΩ·km) |
Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
|
BVV | Minimum | Maximum | BVV | |||||
2×1.5 | 1 | 9.36 | 7.6 | 10.0 | 98.94 | 12.1 | 0.011 | 18 |
2×1.5 | 2 | 9.72 | 7.8 | 10.5 | 103.09 | 12.1 | 0.010 | 18 |
2×2.5 | 1 | 10.56 | 8.6 | 11.5 | 130.99 | 7.41 | 0.010 | 25 |
2×2.5 | 2 | 11.08 | 9.0 | 12.0 | 138.55 | 7.41 | 0.009 | 25 |
2×4 | 1 | 11.50 | 9.6 | 12.5 | 171.31 | 4.61 | 0.0085 | 33 |
2×4 | 2 | 12.10 | 10.0 | 13.0 | 179.24 | 4.61 | 0.0077 | 33 |
2×6 | 1 | 12.52 | 10.5 | 13.5 | 218.41 | 3.08 | 0.0070 | 42 |
2×6 | 2 | 13.24 | 11.0 | 14.0 | 227.77 | 3.08 | 0.0065 | 42 |
2×10 | 1 | 15.64 | 13.0 | 16.5 | 361.55 | 1.83 | 0.0070 | 65 |
2×10 | 2 | 16.70 | 13.5 | 17.5 | 384.71 | 1.83 | 0.0065 | 65 |
2×16 | 2 | 18.80 | 15.5 | 20.0 | 532.01 | 1.15 | 0.0052 | 87 |
2×25 | 2 | 22.64 | 18.5 | 24.0 | 798.61 | 0.727 | 0.0050 | 110 |
2×35 | 2 | 25.72 | 21.0 | 27.5 | 1055.97 | 0.524 | 0.0044 | 140 |
3×1.5 | 1 | 9.8 | 8.0 | 10.5 | 124.61 | 12.1 | 0.011 | 15 |
3×1.5 | 2 | 10.19 | 8.2 | 11.0 | 129.71 | 12.1 | 0.010 | 15 |
3×2.5 | 1 | 11.10 | 9.2 | 12.0 | 168.94 | 7.41 | 0.010 | 21 |
3×2.5 | 2 | 11.66 | 9.4 | 12.5 | 178.67 | 7.41 | 0.009 | 21 |
3×4 | 1 | 12.12 | 10.0 | 13.0 | 228.20 | 4.61 | 0.0085 | 28 |
3×4 | 2 | 12.76 | 10.5 | 13.5 | 238.21 | 4.61 | 0.0077 | 28 |
3×6 | 1 | 13.62 | 11.5 | 14.5 | 307.47 | 3.08 | 0.0070 | 36 |
3×6 | 2 | 14.40 | 12.0 | 15.5 | 319.96 | 3.08 | 0.0065 | 36 |
3×10 | 1 | 16.52 | 14.0 | 17.5 | 476.74 | 1.83 | 0.0070 | 56 |
3×10 | 2 | 17.67 | 14.5 | 19.0 | 507.40 | 1.83 | 0.0065 | 56 |
3×16 | 2 | 20.34 | 16.5 | 21.5 | 726.41 | 1.15 | 0.0052 | 74 |
3×25 | 2 | 24.05 | 20.5 | 26.0 | 1074.22 | 0.727 | 0.0050 | 98 |
3×35 | 2 | 27.31 | 22.0 | 29.0 | 1431.17 | 0.524 | 0.0044 | 120 |
4×1.5 | 1 | 10.51 | 8.6 | 11.5 | 159.43 | 12.1 | 0.011 | 15 |
4×1.5 | 2 | 10.95 | 9.0 | 12.0 | 165.62 | 12.1 | 0.010 | 15 |
4×2.5 | 1 | 11.96 | 10.0 | 13.0 | 216.48 | 7.41 | 0.010 | 21 |
4×2.5 | 2 | 12.59 | 10.0 | 13.5 | 228.55 | 7.41 | 0.009 | 21 |
4×4 | 1 | 13.49 | 11.5 | 14.4 | 296.50 | 4.61 | 0.0085 | 28 |
4×4 | 2 | 14.22 | 12.0 | 15.0 | 309.46 | 4.61 | 0.0077 | 28 |
4×6 | 1 | 15.13 | 12.5 | 16.0 | 398.92 | 3.08 | 0.0070 | 36 |
4×6 | 2 | 15.99 | 13.0 | 17.0 | 414.94 | 3.08 | 0.0065 | 36 |
4×10 | 1 | 17.93 | 15.5 | 19.0 | 594.97 | 1.83 | 0.0070 | 56 |
4×10 | 2 | 19.20 | 16.0 | 20.5 | 633.59 | 1.83 | 0.0065 | 56 |
4×16 | 2 | 22.14 | 18.0 | 35.5 | 916.62 | 1.15 | 0.0052 | 74 |
4×25 | 2 | 27.09 | 22.5 | 28.5 | 1414.08 | 0.727 | 0.0050 | 98 |
4×35 | 2 | 28.84 | 24.5 | 32.0 | 1826.39 | 0.524 | 0.0044 | 120 |
5×1.5 | 1 | 11.31 | 9.4 | 12.0 | 191.08 | 12.1 | 0.011 | 15 |
5×1.5 | 2 | 11.79 | 9.8 | 12.5 | 198.39 | 12.1 | 0.010 | 15 |
5×2.5 | 1 | 12.93 | 11.0 | 14.0 | 260.97 | 7.41 | 0.010 | 21 |
5×2.5 | 2 | 13.63 | 11.0 | 14.5 | 275.46 | 7.41 | 0.009 | 21 |
5×4 | 1 | 15.00 | 12.5 | 16.0 | 370.96 | 4.61 | 0.0085 | 28 |
5×4 | 2 | 15.81 | 13.0 | 17.0 | 387.08 | 4.61 | 0.0077 | 28 |
5×6 | 1 | 16.37 | 13.5 | 17.5 | 482.44 | 3.08 | 0.0070 | 36 |
5×6 | 2 | 17.34 | 14.5 | 18.5 | 501.42 | 3.08 | 0.0065 | 36 |
5×10 | 1 | 19.50 | 17.0 | 21.0 | 725.11 | 1.83 | 0.0070 | 56 |
5×10 | 2 | 20.94 | 17.5 | 22.0 | 771.84 | 1.83 | 0.0065 | 56 |
5×16 | 2 | 24.57 | 20.5 | 26.0 | 1142.09 | 1.15 | 0.0052 | 74 |
5×25 | 2 | 29.61 | 24.5 | 31,5 | 1732.02 | 0.727 | 0.0050 | 98 |
5×35 | 2 | 33.09 | 27.0 | 35.0 | 2272.06 | 0.524 | 0.0044 | 120 |
Notes: Conductor Types–1st type is solid conductor;2nd type is stranded conductor;5th type is stranded soft conductor;
which are suitable for different applications.
We are China Wholesale High Quality Bare Copper Core PVC Insulated Electrical Wire and Cable Building Wire manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 450/750V Cable Products
BV Cale Wire (Building Wire) House Wire
Control/XLPE/Power/Electrical/ Rubber/Insulated Cable
Sell Factory Price 450/750V Types BV 1.5mm2 PVC Copper Electrical Wire Cable
1.5 mm 2.5 mm 4 6 Sq mm Single Core PVC Coated Copper Electric Cable Wire
PVC Insulated Shielded Rvvp Control Cable
BV/BVVB/BVV PVC Insualted Electrical Wire (Housing Electrical Wire)
Popular Cable Products
Hot in Venezuela! Thhn/Thwn Nylon Jacket Electric Wire
All Aluminum Alloy Conductor AAAC Overhead Electric Conductor
IEC60228 Single Multi Core Unarmoured Cu/XLPE/PVC Cover Electric Power Cable
ABC Cable, Aerial Bundled Cable. Overhead Cable.
150mm2 240mm2 300mm2 Low Voltage Aluminum XLPE-PVC 0.6/1kv Power Cable
XLPE Power Cable 3X50mm2 Low Voltage Cables Power Cable
Popular Power Cable Products
Copper Conductor 4 Cores XLPE Insulation PVC Sheath Armoured Power Cable
3 Cores Aluminium Conductor PVC Power Cable
3 Core PVC Insulated Aluminum Electric Power Cable with High Quality
Electrical/Electric Cable N2xy Nayy Nyy XLPE Insulated Steel Armored PVC Sheathed Power Cable
Control 500 B, Control Cable, 300/500 V, Flexible Cu/PVC/PVC (IEC 60228/DIN VDE 0295)
Electric Wires Cables Insulated Copper Wire Fluoroplastic Insulation Wire
Popular wuhancable Products
XLPE /PVC (Cross-linked polyethylene) Insulated Electric Power Cable
USA Sizes ASTM B232 Overhead Conductor Steel Reinforced ACSR Dotterel
Hot Sale All Aluminum Conductor
Copper Insulated Armourd PE Sheath Conductor
Tags: 450/750V Cable, Cable, Power Cable, wuhancable