0.6/1kv Type Mv PVC/Swa/PVC 70mm 4 Core Copper Cable with Armored
0.6/1kv Type Mv PVC/Swa/PVC 70mm 4 Core Copper Cable with Armored image
Get Latest Price Request a quote
Quick Details
Product Details
0.6/1KV type MV PVC/SWA/PVC 70mm 4 core copper cable with armored
Application
Armored copper cable is a very innovative concept for overhead power distribution as compared to the conventional bare conductor overhead distribution system.
It provides higher level of safety and reliability, lower power losses and ultimate system economy by reducing installation, maintenance and operative cost.
Caledonian LV Aerial Bundle Cables are designed to supply 600/1000 volt aerial service for temporary service at construction sites, as a service drop (power pole to service entrance), as a secondary cable (pole to pole) or street lighting.
This over-head cable provides reinforced insulation acc. IEC 61140 and fulfill therefore Class II acc. IEC 61140. It is not flame retardant. But this could be if requested change to a flame retardant cable.
Standard
Basic design to BS 7870 / TNB Specification(IEC 60502) / HD 626 S1 / NFC 33-209 / AS/NZS 3560-1 standards
Construction
| Conductor | Aluminium conductor, round stranded compressed (RM). |
| Insulation | XPLE compound, UV-resistant. |
| Core Identification | 1, 2 resp. 3 raised longitudinal ribs on the surface of the cores. The surface of the neutral core should have at least 12 ribs for cross-sections up to 50 mm² and a minimum of 16 ribs for cores above 50 mm². In the case of five core bundles the surface of the protective core should be smooth. |
Electrical Properties
| Rated Voltage | 0.6/1kV |
| Test Voltage | 4 Veff kV |
| Minimum Laying Temperature | -20°C |
| Operating Temperature | -40°C~ +90°C |
| Maximum Short-circuit Temperature | 250°C |
| Maximum Conductor Temperature | 80°C |
| Minimum Bending Radius | 18×OD |
Construction Parameters
BS 7870
| Number of Cores x Nominal Cross Section | Overall Diameter | Weight | Maximum Conductor Resistance | Minimum Breaking Load | Current Rating |
|---|---|---|---|---|---|
| No.×mm² | mm | Kg/Km | Ω/Km | KN | A |
| 1×16 RM | 8.0 | 74 | 1.910 | 2.5 | 72 |
| 1×25 RM | 9.0 | 106 | 1.200 | 4.0 | 107 |
| 1×35 RM | 10.5 | 138 | 0.868 | 5.5 | 132 |
| 1×50 RM | 11.8 | 182 | 0.641 | 8.0 | 165 |
| 1×70 RM | 13.0 | 252 | 0.443 | 10.7 | 205 |
| 1×95 RM | 15.4 | 333 | 0.320 | 13.7 | 240 |
| 1×120 RM | 17.0 | 408 | 0.253 | 18.6 | 290 |
| 1×150 RM | 19.0 | 502 | 0.206 | 23.2 | 334 |
| 1×185 RM | 21.0 | 611 | 0.164 | 28.7 | 389 |
| 1×240 RM | 24.0 | 801 | 0.125 | 37.2 | 467 |
| 2×16 RM | 15.6 | 147 | 1.910 | 2.5 | 72 |
| 2×25 RM | 18.0 | 208 | 1.200 | 4.0 | 107 |
| 2×35 RM | 20.0 | 277 | 0.868 | 5.5 | 132 |
| 2×50 RM | 23.5 | 361 | 0.641 | 8.0 | 165 |
| 2×70 RM | 25.4 | 505 | 0.443 | 10.7 | 205 |
| 2×95 RM | 30.3 | 666 | 0.320 | 13.7 | 240 |
| 2×150 RM | 38.0 | 1004 | 0.206 | 23.2 | 334 |
| 4×16 RM | 18.8 | 286 | 1.910 | 2.5 | 72 |
| 4×25 RM | 21.2 | 430 | 1.200 | 4.0 | 107 |
| 4×35 RM | 24.1 | 553 | 0.868 | 5.5 | 132 |
| 4×50 RM | 27.8 | 746 | 0.641 | 8.0 | 165 |
| 4×70 RM | 31.8 | 1009 | 0.443 | 10.7 | 205 |
| 4×95 RM | 37.8 | 1332 | 0.320 | 13.7 | 240 |
| 4×120 RM | 54.4 | 1632 | 0.253 | 18.6 | 290 |
| 4×50 + 1×25 RM | 31.9 | 814 | 0.641/1.200 | 8.0/4.0 | 165/107 |
| 4×50 + 1×35 RM | 31.9 | 845 | 0.641/0.868 | 8.5/5.5 | 165/132 |
| 4×70 + 1×25 RM | 36.0 | 1105 | 0.443/1.200 | 10.7/4.0 | 205/107 |
| 4×70 + 2×25 RM | 40.0 | 1217 | 0.443/1.200 | 10.7/4.0 | 205/107 |
| 4×95 + 1×25 RM | 41.8 | 1438 | 0.320/1.200 | 13.7/4.0 | 240/107 |
| 4×95 + 2×25 RM | 42.0 | 1544 | 0.320/1.200 | 13.7/4.0 | 240/107 |
| 4×120 + 1×25 RM | 59.0 | 2050 | 0.253/1.200 | 18.6/4.0 | 290/107 |
Other cross-sections can be offered upon request.
TNB Specification(IEC 60502)
| Number of Cores x Nominal Cross Section | Overal Diameter | Weight | Maximum Conductor Resistance | Minimum Breaking Load | Current Rating |
|---|---|---|---|---|---|
| No.×mm² | mm | Kg/Km | Ω/Km | KN | A |
| 1×16+1×25 RM | 15.3 | 160 | 1.910 | 2.5 | 72 |
| 3×16+1×25 RM | 19.0 | 290 | 1.200 | 4.0 | 107 |
| 3×25+1×25 RM | 23.2 | 400 | 0.868 | 5.5 | 132 |
| 3×35+1×25 RM | 25.6 | 500 | 0.641 | 8.0 | 165 |
| 3×50+1×35 RM | 30.0 | 680 | 0.443 | 10.7 | 205 |
| 3×70+1×50 RM | 34.9 | 920 | 0.320 | 13.7 | 240 |
| 3×95+1×70 RM | 40.6 | 1270 | 0.253 | 18.6 | 290 |
| 3×120+1×70 RM | 44.1 | 1510 | 0.206 | 23.2 | 334 |
| 3×150+1×95 RM | 49.2 | 1870 | 0.164 | 28.7 | 389 |
| 3×185+1×120 RM | 54.9 | 2340 | 0.125 | 37.2 | 467 |
| 3×25+1×25+1×16 RM | 23.2 | 470 | 1.910 | 2.5 | 72 |
| 3×35+1×25+1×16 RM | 25.6 | 560 | 1.200 | 4.0 | 107 |
| 3×50+1×35+1×16 RM | 30.0 | 740 | 0.868 | 5.5 | 132 |
| 3×70+1×50+1×16 RM | 34.9 | 980 | 0.641 | 8.0 | 165 |
| 3×95+1×70+1×16 RM | 40.6 | 1330 | 0.443 | 10.7 | 205 |
| 3×120+1×70+1×16 RM | 44.1 | 1580 | 0.320 | 13.7 | 240 |
| 3×150+1×95+1×16 RM | 49.2 | 1940 | 0.206 | 23.2 | 334 |
| 3×185+1×120+1×16 RM | 54.9 | 2410 | 1.910 | 2.5 | 72 |
Other cross-sections can be offered upon request.
HD 626 S1
| number of cores x nominal cross section | outer diameter | total weight | max. conductor- resistance | min. breaking load of conductor strand | current rating in the air 1) |
|---|---|---|---|---|---|
| mm² | ca. mm | ca. kg/km | Ohm/km | kN | A |
| 2x 16 RM | 15.6 | 147 | 1.910 | 2.5 | 72 |
| 2x 25 RM | 18.0 | 208 | 1.200 | 4.0 | 107 |
| 2x 35 RM | 20.0 | 277 | 0.868 | 5.5 | 132 |
| 2x 50 RM | 23.5 | 361 | 0.641 | 8.0 | 165 |
| 4x 16 RM | 18.8 | 286 | 1.910 | 2.5 | 72 |
| 4x 25 RM | 21.2 | 430 | 1.200 | 4.0 | 107 |
| 4x 35 RM | 24.1 | 553 | 0.868 | 5.5 | 132 |
| 4x 50 RM | 27.8 | 746 | 0.641 | 8.0 | 165 |
| 4x 70 RM | 31.8 | 1009 | 0.443 | 10.7 | 205 |
| 4x 95 RM | 37.8 | 1332 | 0.320 | 13.7 | 240 |
| 4x 120 RM | 54.4 | 1632 | 0.253 | 18.6 | 290 |
| 4x 35 + 1x 35 RM | 30.0 | 694 | 0.868/0.868 | 5.5/5.5 | 132/132 |
| 4x 50 + 1x 25 RM | 31.9 | 814 | 0.641/1.200 | 8.0/4.0 | 165/107 |
| 4x 50 + 1x 35 RM | 31.9 | 845 | 0.641/0.868 | 8.5/5.5 | 165/132 |
| 4x 70 + 1x 25 RM | 36.0 | 1105 | 0.443/1.200 | 10.7/4.0 | 205/107 |
| 4x 70 + 2x 25 RM | 40.0 | 1217 | 0.443/1.200 | 10.7/4.0 | 205/107 |
| 4x 70 + 1x 35 RM | 36.2 | 1150 | 0.443/0.868 | 10.7/5.5 | 205/132 |
| 4x 70 + 2x 35 RM | 40.1 | 1289 | 0.443/0.868 | 10.7/5.5 | 205/132 |
| 4x 95 + 1x 25 RM | 41.8 | 1438 | 0.320/1.200 | 13.7/4.0 | 240/107 |
| 4x 95 + 1x 35 RM | 41.8 | 1467 | 0.320/0.868 | 13.7/5.5 | 240/132 |
| 4x 95 + 2x 25 RM | 42.0 | 1544 | 0.320/1.200 | 13.7/4.0 | 240/107 |
Other cross-sections can be offered upon request.
NFC 33-209
| Number of Cores x Nominal Cross Section | Overal Diameter | Weight | Maximum Conductor Resistance | Minimum Breaking Load | Current Rating |
|---|---|---|---|---|---|
| No.×mm² | mm | Kg/Km | Ω/Km | KN | A |
| 2×10 RM | 12.8 | 93 | 3.080 | 1.5 | 38 |
| 4×10 RM | 15.4 | 183 | 3.080 | 1.5 | 38 |
| 2×16 RM | 14.8 | 129 | 1.910 | 2.3 | 72 |
| 2×16 RN + 2×1.5 RE | 14.8 | 176 | 1.910/12.100 | 2.3 | 72 |
| 4×16 RM | 17.8 | 257 | 1.910 | 2.3 | 72 |
| 4×16 RN + 2×1.5 RE | 17.8 | 304 | 1.910/12.100 | 2.3 | 72 |
| 2×25 RM | 18.0 | 202 | 1.200 | 3.8 | 107 |
| 2×25 RM + 2×1.5 RE | 18.0 | 249 | 1.200/12.100 | 3.8 | 107 |
| 4×25 RM | 21.7 | 404 | 1.200 | 3.8 | 107 |
| 4×25 RM + 2×1.5 RE | 21.7 | 451 | 1.200/12.100 | 3.8 | 107 |
| 2×35 RM | 20.8 | 269 | 0.868 | 5.2 | 132 |
| 2×35 RM + 2×1.5 RE | 20.8 | 316 | 0.868/12.100 | 5.2 | 132 |
| 4×35 RM | 25.1 | 539 | 0.868 | 5.2 | 132 |
| 4×35 RM + 2×1.5 RE | 25.1 | 586 | 0.868/12.100 | 5.2 | 132 |
| 2×50 RM | 23.4 | 352 | 0.641 | 7.6 | 165 |
| 2×50 RM + 2×1.5 RE | 23.4 | 399 | 0.641/12.100 | 7.6 | 165 |
| 1×54.6 RM + 3×25 RM | 21.7 | 507 | 0.630/1.200 | 3.8 | 107 |
| 1×54.6 RM + 3×25 RM + 1×16 RM | 24.3 | 573 | 0.630/1.200/1.910 | 3.8/2.3 | 107/72 |
| 1×54.6 RM + 3×25 RM + 2×16 RM | 29.7 | 639 | 0.630/1.200/1.910 | 3.8/2.3 | 107/72 |
| 1×54.6 RM + 3×25 RM + 3×16 RM | 31.1 | 705 | 0.630/1.200/1.910 | 3.8/2.3 | 107/72 |
| 1×54.6 RM + 3×35 RM | 25.1 | 615 | 0.630/0.868 | 5.2 | 132 |
| 1×54.6 RM + 3×35 RM + 1×16 RM | 28.1 | 680 | 0.630/0.868/1.910 | 5.2/2.3 | 132/72 |
| 1×54.6 RM + 3×35 RM + 2×16 RM | 34.3 | 748 | 0.630/0.868/1.910 | 5.2/2.3 | 132/72 |
| 1×54.6 RM + 3×35 RM + 3×16 RM | 35.9 | 814 | 0.630/0.868/1.910 | 5.2/2.3 | 132/72 |
| 1×54.6 RM + 3×35 RM + 1×25 RM | 28.1 | 714 | 0.630/0.868/1.200 | 5.2/3.8 | 132/107 |
| 1×54.6 RM + 3×50 RM | 28.2 | 741 | 0.630/0.641 | 7.6 | 165 |
| 1×54.6 RM + 3×50 RM + 1×16 RM | 31.6 | 806 | 0.630/0.641/1.910 | 7.6/2.3 | 165/72 |
| 1×54.6 RM + 3×50 RM + 2×16 RM | 38.6 | 875 | 0.630/0.641/1.910 | 7.6/2.3 | 165/72 |
| 1×54.6 RM + 3×50 RM + 3×16 RM | 40.4 | 940 | 0.630/0.641/1.910 | 7.6/2.3 | 165/72 |
| 1×54.6 RM + 3×50 RM + 1×25 RM | 31.6 | 841 | 0.630/0.641/1.200 | 7.6/3.8 | 165/107 |
| 1×54.6 RM + 3×70 RM | 33.0 | 950 | 0.630/0.443 | 10.2 | 205 |
| 1×54.6 RM + 3×70 RM + 1×16 RM | 37.0 | 1014 | 0.630/0.443/1.910 | 10.2/2.3 | 205/72 |
| 1×54.6 RM + 3×70 RM + 2×16 RM | 45.2 | 1083 | 0.630/0.443/1.910 | 10.2/2.3 | 205/72 |
| 1×54.6 RM + 3×70 RM + 3×16 RM | 47.3 | 1148 | 0.630/0.443/1.910 | 10.2/2.3 | 205/72 |
| 1×54.6 RM + 3×70 RM + 1×25 RM | 37.0 | 1048 | 0.630/0.443/1.200 | 10.2/3.8 | 205/107 |
| 1×54.6 RM + 3×70 RM + 2×25 RM | 45.2 | 1150 | 0.630/0.443/1.200 | 10.2/3.8 | 205/107 |
| 1×54.6 RM + 3×70 RM + 3×25 RM | 47.3 | 1250 | 0.630/0.443/1.200 | 10.2/3.8 | 205/107 |
| 1×54.6 RM + 3×95 RM | 37.4 | 1176 | 0.630/0.320 | 13.5 | 240 |
| 1×54.6 RM + 3×95 RM + 1×16 RM | 41.9 | 1243 | 0.630/0.320/1.910 | 13.5/2.3 | 240/72 |
Other cross-sections can be offered upon request.
AS/NZS 3560 Part 1
| Number of Cores x Nominal Cross Section | Overall Diameter | Weight | Minimum Breaking Load | Current Rating |
|---|---|---|---|---|
| No.×mm² | mm | Kg/Km | KN | A |
| 2×16 RM | 15.0 | 140 | 4.4 | 78 |
| 2×25 RM | 17.6 | 210 | 7.0 | 105 |
| 2×35 RM | 19.6 | 270 | 9.8 | 125 |
| 2×50 RM | 22.8 | 370 | 11.4 | 150 |
| 2×95 RM | 30.6 | 680 | 15.3 | 230 |
| 3×25 RM | 19.0 | 310 | 8.8 | 97 |
| 3×35 RM | 21.1 | 410 | 9.8 | 120 |
| 3×50 RM | 24.6 | 550 | 11.4 | 140 |
| 4×16 RM | 18.1 | 290 | 8.8 | 74 |
| 4×25 RM | 21.2 | 410 | 14.0 | 97 |
| 4×35 RM | 23.7 | 550 | 19.6 | 120 |
| 4×50 RM | 27.5 | 740 | 28.0 | 140 |
| 4×70 RM | 31.9 | 1000 | 39.2 | 175 |
| 4×95 RM | 36.9 | 1370 | 53.2 | 215 |
| 4×120 RM | 40.6 | 1690 | 67.2 | 250 |
| 4×150 RM | 43.9 | 2020 | 84.0 | 280 |
Other cross-sections can be offered upon request.
We are China 0.6/1kv Type Mv PVC/Swa/PVC 70mm 4 Core Copper Cable with Armored manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 1kv Armored Cable Products
0.6/1kv Type Mv PVC/Swa/PVC 2.5mm 4 Core Copper Power Cable with Armored
Low Voltage XLPE Cable with Steel Tape Armored and Multi Cores
Cu (Al) 4 Core XLPE Insulated PVC Sheathed 16mm Armoured Cable
0.6/1kv PVC/Swa/PVC 35mm 4 Core Copper Armoured Cable
0.6/1kv PVC Insulated PVC Sheated 2.5mm 3 Core Copper Power Cable with Swa Armored
0.6/1kv Armored Cable 3X120mm Aluminum Cable with Steel Tape Armored
Popular jytopcable Products
B857 ASTM Standard Aluminum Conductor Steel Supported Acss/Tw Trapezoidal Conductor
Middle Voltage Copper or Aluminum Conductor XLPE Insulated Power Cable
Bare Conductor AAAC 6201 ASTM Standards
450/750V PVC Control Cable Factory with 25 Years' Experience
Galvanized Steel Wire Professional Manufacturer
3X95mm2 Aluminium XLPE Insulated Armoured Yjv Electrical Power Cable
Popular PVC Insulated Cable Products
PVC Insulated Steel Tape Armored Power Cable
450/750V PVC Insulated Cable Communication Used as Power
Flame Retardant Multicore Copper Conductor PVC Insulated Control Shield Cable for Protection
0.6/1kv Armored or Non-Armored PVC Insulated Power Cable Wire
Yavv Nayy Aluminum Cable PVC Insulated Cables with Aluminium Conductor
0.6/1kv PVC Insulated and Sheathed Copper/Aluminum Power Cable with IEC Standard
Popular Steel Wire Armoured Cable Products
11kv 3core150mm2 240mm2 XLPE Insulation Sta Swa Armored Power Cable
Cu (Al) 4 Core XLPE Insulated PVC Sheathed 16mm Armoured Cable
6/10kv 8.7/15kv XLPE Insulation Fine/Thick Steel Wire Armored Power Cable
0.6/1kv PVC Insulated PVC Sheated 2.5mm 3 Core Copper Power Cable with Swa Armored
3X185mm2 Copper Conductor XLPE Insulated Swa Steel Wire Armoured Electrical Cable
Tags: 1kv Armored Cable, jytopcable, PVC Insulated Cable, Steel Wire Armoured Cable