33kv Sz11 Type on-Load Tap Changer Transformers IEC
33kv Sz11 Type on-Load Tap Changer Transformers IEC image
Get Latest Price Request a quote
Quick Details
Product Details
| 1 | Low loss, therefore significantly energy-saving. The average no-load loss is 35% lower, and the load loss 10~20% lower, than prescribed by the present National standard GB/T 6451. |
| 2 | The core laminations are made up from imported high-quality cold-rolled grain-oriented silicon steel sheets with miter joints and without punched holes, and are stacked without the upper yoke sheets in place. After stacking, the core is pressed integrally and finally glued together by epoxy resin on the cut edges, so that the three limbs and the upper and lower yokes are bonded together into a rigid, vertically straightened entity, together with the plate-type upper and lower frame |
| 3 | Zigzag directed flow of oil are provided within the windings, so that all parts of the windings can be cooled more evenly, thus reducing the temperature rise of the windings as a whole as well as the hot-spot temperature rise, prolonging the service life of transformers. |
| 4 | The regulating winding is a separate winding, apart from the high voltage main winding. In this way, total ampere-turn balance between windings can be obtained irrespective of the tapping position; and the axial electrodynamic force during short circuit can be much reduced, thus upgrading the short circuit withstand capability of the transformer as a whole. All the windings are perfectly dried before assembly. The radial clearances between windings and between low voltage winding and core are filled with pre-dried vertical spacers and insulating cylinders in such a way that the windings are tightly together radially with practically ‘zero’ allowance between them. |
| 5 | The windings of one phase are assembled into an integral phase block before placing onto the core. The low voltage winding is wound directly on strong thick paper cylinder. Vertical spacer strips are provided in spaces between windings and outside the outermost winding. The radial dimensions of all windings are kept within strict tolerance, so that a rigid winding phase block are obtained, capable of withstanding all the radial short-circuit forces encountered in service, and the possibility of buckling of the inner winding is obviated. Axially, the height of all windings is kept within close tolerance. Horizontal spacers between discs of a winding are pre-densified. The assembled winding phase black are pressed up and down by single support and pressure plates after careful adjustment of the heights of individual windings. Axial pressures are co-ordinated with the calculated short circuit force, so that the capability of the transformer to withstand axial short-circuit force is much increased. |
| 6 | The winding manufacture, winding assembly, and core and winding assembly work are all proceeded in totally closed clean rooms inside workshops. The cleanliness and temperature stability requirement of the area are the same as that required for the manufacture of 500kV class transformers. The final vapor phase drying of the core and coil assembly is practically a further cleaning process. |
| 7 | Core frames in the form of a flat plate are used for clamping the core, and are joined together by side beams. The core and coil assembly is fixed in the tank, being positioned against the tank at six sides rigidly, such that there can be no displacement of the assembly due to impacts during transport. Three-dimensional impact recorders are installed on transformers during transport to detect whether or not unacceptable impact force has been experienced and displacement of the core and coil assembly occurred during transportation. If not, lifting of the core and coil assembly out of the tank is not necessary. Flat cover permits the bushings to be mounted in a vertical position, thus eliminating oil leakage because of uneven pressure on the gasket. |
| 8 | Transformer tanks are fabricated with steel plates wide enough so that there are no weld joints on each surface. The steel plates for tank walls are pressed into corrugated shape to increase mechanical strength and to reduce noise due to vibration of the tank wall. Secondary wirings are housed within stainless steel conduits and ended at terminals in a stainless steel control cabinet, resulting in higher reliability and giving a neat appearance. |
| 9 | Diaphragm membrance is provided within the conservator, preventing direct contact of oil with air, protecting the oil from aging, thereby prolonging the service life of oil. Magnetic oil-level gauge reflects correctly the oil level in conservator. Flat plate-type radiators effectively cool down the transformer. |
| 10 | Quality assurance rules are observed from the very beginning of acquisition of raw materials and components. No rusting, colliding, scratching or hammering is allowed for steel plate. Special attention is paid to those parts susceptible to oil leakage. All the gasket groove surfaces are carefully machined, and limits are provided to prevent the gasket material from being compressed over its elastic limit. The transformer tank is integrally shot-blasted, and burrs and welding slag are thoroughly removed. Radiators and other component parts are tested in accordance with their respective service condition. Usually the flanges of upper and lower parts of the tank are bolted together with double gasket grooves in their jointing surface and kept tight with high quality gasket material, effectively preventing oil leakage from the jointing surface. If required by the customer,the upper and lower part of the tank can also be welded oil tight. |
| 11 | High quality paint is applied as surface finish of the tank and exposed steel parts, after shot-blasting and pretreatment, thus ensuring a durable life and glossy surface. |
| 12 | Quality assurance rules are also observed for all insulating parts, from raw material to final assembly. Strict regulations are observed for drying, wrapping and storage, preventing the absorption of moisture, swelling, and deformation. Finished spacers and pressure rings are all stored in practically isothermal oven. Finished windings, after pressing and adjustment are conserved in specially made isothermal cylinders. For the core and oil assembly, the time interval between lifting out from oven and tanking is strictly controlled, so that no significant absorption of moisture can occur due to exposure. Technical Specification Factory Inspection |
We are China 33kv Sz11 Type on-Load Tap Changer Transformers IEC manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Amorphous Transformer Products
33kv S11 Type off-Circuit Tap Changing Electronic Transformers
Three Phase Pad Mount Mobile Power Distribution Transformers 11kv
Step Voltage Regulator 11kv Voltage Transformer
Three Phase Overhead Pole Mounted Distribution Transformer IEC Standard
Pad Mount Mobile Three Phase Power Distribution Transformer
S11 Type 33kv off-Circuit Tap Changing Transformers
Popular Oil Transformet Products
Type Sc (B) 11-24kv Dry-Type Transformer Dimensions with Protection Enclosure
33kv 38kv Oil-Immersed Power Transformer
Single Phase Overhead Step up Step Down Distribution Transformer 11kv
11kv Type Sc10-30~1000kVA Dimensions with Protection Enclosure
S11 Type 33kv off-Circuit Tap Changer Transformers
Rectifier Special Transformer 11kv 33kv
Popular Power Transformer Products
Pad Mounted Compact Type Three Phase Distribution Transformer
Transformer Parts of 417A Tri Clamp Bushing With High Quality
Support customized Transformer Parts High Temperature resistant F Grade Nylon bushing
24kV Silicone Rubber Composite Suspension Insulator for power transformer
De-energized linearity tap-changer (35kV and below)
D11 Single Phase Oil Immersed Transformer 11kv
Popular silverstone-electric Products
230kv Level Oil-Immersed Power Transformer IEC Standard
35kv Arc Furnace Transformer Special Transformer
11kv Prefabricated Substation Transformer Enclosure
High Voltage Ceramic Pin Type Porcelain Insulator ANSI
33kv to 132kv Polymer Surge Arrester for Neutral of Transformer
11kv D11 Single-Phase Oil-Immersed Transformer
Tags: Amorphous Transformer, Oil Transformet, Power Transformer, silverstone-electric
