Kw -2 Insulation Puncture Cable Clamp (connector)
Kw -2 Insulation Puncture Cable Clamp (connector) image
Get Latest Price Request a quote
Basic Info.
Product Description
Product Description
The insulation puncture clamp (connector) is mainly composed of an insulation shell, a puncture blade, a waterproof rubber pad, and a torque bolt. When making a cable branch connection, insert the branch cable into the branch cap and determine the branch position of the main line, then use a socket wrench to tighten the torque nut on the clamp. With the tightening of the torque nut, the upper and lower parts of the clamp have hidden insulators with piercing blades At the same time, the arc-shaped sealing rubber pad wrapped around the piercing blade is gradually clinging to the cable insulation layer, and the piercing blade also begins to pierce the cable insulation layer and metal conductor. When the sealing degree of the sealing rubber pad and insulating grease and the contact between the puncture blade and the metal body reach the best effect, the torque nut will automatically fall off, at this time, the installation is completed and the contact point sealing and electrical effect reach the best.
Insulation piercing clamps can be divided into 1KV, 10KV, and 20KV insulation piercing clamps according to voltage classification.
According to the functional classification, it can be divided into ordinary insulation piercing wire clips, electrical inspection grounding insulation piercing wire clips, lightning protection and arc proof insulation piercing wire clips, and fireproof insulation piercing wire clips
Technical parameters
Product features and advantage
Structural features:
1. Puncture structure, simple installation, no need to peel the insulated wire;
2. Torque nut, constant puncture pressure, ensure good electrical connection without damaging the wire,
3. Self sealing structure, moisture-proof, water-proof and anti-corrosion, extending the service life of insulated conductors and clamps
4. Special contact blade is used for copper (aluminum) butt joint and copper aluminum transition
5. The electrical contact resistance is small, and it is less than 1.1 times of the resistance of equal length branch conductor, meeting the DL/T765.1-2001 standard
6. Special insulating shell, anti light and environmental aging, dielectric strength>12KV
7. Curved surface design, applicable to the connection of the same (reducing) diameter conductor, with a wide connection range (0.75mm2-400mm2)
Product advantages:
1. Simple installation: cable branch can be made without stripping the insulation skin of the cable, and the joint is completely insulated. It is not necessary to cut off the main cable, and branches can be made at any position of the cable. The installation is simple and reliable. It can be installed with electricity only by using a socket wrench.
2. Safety in use: the connector is resistant to twisting, shockproof, waterproof, flame retardant, and electrochemical corrosion aging, requiring no maintenance. It has been successfully used for more than 30 years.
3. Cost saving: the installation space is very small, saving the cable tray and civil engineering costs. For application in buildings, there is no need for terminal box, distribution box, cable return, and cable investment. The cost of cable+piercing clamp is lower than that of other power supply systems, which is only about 40% of the plug-in bus and about 60% of the prefabricated branch cable.
Product installation
1. Adjust the nut of the piercing clamp to the proper position, and insert the branch wire into the branch wire cap completely.
2. Insert the main line. If the main line has two layers of insulation, a certain length of outer insulation must be stripped at the connection position.
3. Put the main/branch line in a proper position and keep them parallel. First, tighten the nut by hand to fix the clamp.
4. Tighten the nut evenly with a socket wrench of the corresponding size until the top breaks off and the installation is complete.
Installation of the double-screw insulation piercing clamp:
1. Unscrew the clamp first and snap the main wire into the main wire groove. Do not jam the main wire and the knife ruler crookedly. Pay attention to whether the wire diameter range corresponds to this wire clip.
2. Put the branch line into the branch line slot. The precautions are the same as above.
3. Tighten with a socket wrench. Open-end wrenches are disabled.
4. Note that the two nuts should be screwed down synchronously in sequence.
5. When tightened to a certain strength, the constant torque nut is twisted off. The installation is complete.
Product details
Products real shot
A corner of the production workshop
Product packaging
Product application case
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
We are China Kw -2 Insulation Puncture Cable Clamp (connector) manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Cable Wire Clamp Products
DTG 4-1000mm2 4.2-23mm Tube Pressed Copper Connecting Terminal Tinned Copper Cable Lug
Byd 35-240mm2 1-10kv Overhead Insulated Power Line Electric-Check Grounding Ring Earthing Ring
Ty 35-630mm² 20-70mm Electric Power Fittings Hydraulic T-Clamp Single Conductor Branch Clamp
Dtga (SC) 4-1000mm2 6.2-22.5mm Peephole Copper Connecting Terminal Cable Lugs
Jgpd (H) 45-130mm High Quality Three Core High Voltage Cable Clamp Cable Retaining Clip
Ot 10-1000A 5.2-18.2mm Copper Passing Through Connecting Terminal Cable Lugs
Popular cnkcele Products
Nll 5-46.5mm 40-120kn 10kv Overhead Insulated Conductor Fittings Bolt Type Tension Clamp
Lsg/Lzt 1/10/35kv 1-5 Cores 25-400mm² Cable Cold Shrink Finger Sleeve
Fpq 10/35kv Outdoor High Voltage Composite Silicone Rubber Needle Lightning Insulator
Popular Kw -2 Insulation Puncture Cable Clamp (connector) Products
Popular Overhead Conductor Clamp Products
Ny 185-800mm² Tension Clamp for Heat-Resistant Aluminum Alloy Stranded Wire
Es/PS Series 1kv 25-95mm² Fixed Suspension Clamp of Overhead Cable
Fhj 10-20kv 35-240mm 2 Cable Lightning Protection Device Lightning Protection Wire Clamp
PA Series 1kv 4-120mm² Overhead Cable Fixed Insulation Plastic Tensioning Clamp
Dtl-2 8.2-12.8mm 16-630mm2 Export Type Copper Aluminum Transition Connecting Wire Terminal Cable Lug
Jgw 40-165mm 1-3 Core High Voltage Cable Fixing Clamp Cable Hoop
Tags: Cable Wire Clamp, cnkcele, Kw -2 Insulation Puncture Cable Clamp (connector), Overhead Conductor Clamp
