High Voltage Composite/ Ceramic Housed Lightning Arrester 15kv
High Voltage Composite/ Ceramic Housed Lightning Arrester 15kv image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
| Type | YH10W5-15/41.2 | 4/10µS High current impulse kA | 100 |
| Rated voltage———kV | 15 | Lightning impulse withstand kV | 110 |
| MCOV —————-kV | 12.7 | Power frequency voltage withstand(dry/wet)kV | 28 |
| Nominal Current——-kA | 10 | 0.1S TOV————–kV | 18 |
| Residual voltage of steep impulse—-at 5kA(kV) | 44.5 | 1S TOV—————-kV | 17.25 |
| 8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 41.2 | 10S TOV—————kV | 16.5 |
| Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 31.5 | 1200S TOV————-kV | 15 |
| 1mA D.C reference voltage (kV) | 21.2 | Creepage distance —-mm | 500 |
| Line discharge level | 1 | Material employed in series non-linear resistor | Zinc Oxide |
| 2mS long duration impulse current A | 400 | Material of housing | silicone rubber |
Working condition:
| Environment temperature: -40–+40 degree | |||||||
| altitude:<1000m | |||||||
| 48HZ<Rated frequency<62HZ | |||||||
| Power frequency voltage should not be more than continuous running voltage | |||||||
| Max wind speed should be less than 35m/s | |||||||
| Earthquake intensity should be less than 7 degree | |||||||
| If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China High Voltage Composite/ Ceramic Housed Lightning Arrester 15kv manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Medium Voltage 3-36kv Silicone Mcov 17kv Lightning Diverter with Disconnector
China High Voltage Centre Break Disconnector 126kv
Porcelain Insulator High Voltage Insulator
0.25kv~765kv Silicon Rubber (Ceramic) Housed Metal Oxide Gapless Surge Arrester with Kema Type Test
Horizontal Drive Boxes for Hv Disconnect Switches
12kv Hv Porcelain Ceramic Drop out Fuse with Fuse Tube
Popular Lightning Arrester Products
21kv Silicon Type Surge Arrester Cmr5w-21
Surge Arrester 18kv 5ka for Distribution Use
Dead End Clamp for Insulated Neutral Messenger
10ka 18kv Lightning Arrester Yh10W-18kv-21kv Surge Arrester
Yh5w-9, Sharp Head 5kv 9ka Surge Arrester
Popular Surge Arrester Products
Fuyang Electricity Bracket/ Aluminium Grading Ring for Surge Arrester
36kv Outdoor Polymer & Composite Surge Arrester
Lighting Arrestor Surge Arrester Lightning Protector Surge Protector
Hy10wz-100/260 Zinc-Oxide Arrester
Popular Surge Arresters Products
21kv 10ka Polymer Housed Zinc Oxide Surge Arrester
Rated Voltage 21kv Mcov 17kv Creepage Distance 662mm Arrestor with Polymer Housed
24kv/5ka Polymeric Housed Zinc Oxide Surge Arrester
Nominal Current 5ka Silicone Polymeric Housed Lightening Arrester
10ka Power Station Type Ceramic ZnO Surge Diverters with Silicone Housed
Kema Report Rated Voltage 18kv Moa Metal Oxide 3 Phase Lighting Arrester
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters