Rated Voltage 132kv Rated Current 10ka Station Class Gapless Surge Diverter
Rated Voltage 132kv Rated Current 10ka Station Class Gapless Surge Diverter image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
Type | Y10W5-108/281 |
Rated Voltage———kV | 108 |
MCOV —————-kV | 86 |
Nominal Current——-kA | 10 |
Residual voltage of steep impulse—-at 5kA(kV) | 325 |
8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 274 |
Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 215 |
1mA D.C reference voltage (kV) | 157 |
Line discharge level | 3 |
2mS long duration impulse current A | 850 |
4/10µS High current impulse kA | 100 |
Lightning impulse withstand kV | 550 |
Power frequency voltage withstand(dry/wet)kV | 230 |
0.1S TOV————–kV | 129.6 |
1S TOV—————-kV | 124.2 |
10S TOV—————kV | 118.8 |
1200S TOV————-kV | 108 |
Creepage distance —-mm | 3906 |
Material employed in series non-linear resistor | Zinc Oxide |
Working condition:
Environment temperature: -40–+40 degree | |||||||
altitude:<1000m | |||||||
48HZ<Rated frequency<62HZ | |||||||
Power frequency voltage should not be more than continuous running voltage | |||||||
Max wind speed should be less than 35m/s | |||||||
Earthquake intensity should be less than 7 degree | |||||||
If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Rated Voltage 132kv Rated Current 10ka Station Class Gapless Surge Diverter manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
High Quality Metal Oxide Gapless Lightning Surge Protective Arrester
Latest Electrical Equipment 444kv High Voltage Surge Protector Arresters
Polymer Housed Transformer Protector Arrestor Lightning
Surge Arrester Composite Insulator
Wholesale Price Zinc Oxide Varistor Blocks for Lightning Arrester 11kv
High Voltage Substation Lightning Surge Arresters
Popular Lightning Arrester Products
11kv Zinc Oxide Surge Arrester
33kv Composite Surge Arrester Lightning Arrester Metal Oxide Gapless Polymer Synthetic Polymeric
33kv Polymeric Housed Metal-Oxide Lightning Arrester Without Gaps
Substation Types of 15kv 33 Kv Outdoor Silicon Rubber Lightning Arrester
Yh10W-18, Sharp Head 18kv 10ka Surge Arrester Surge Protector
Popular Surge Arrester Products
33kv High Voltage Surge Arrester for Distribution Line
33kv 10ka High Quality Silicone Housed Gapless Surge Diverters
Polymer Housing Surge Arrester 5ka, 18kv
12kv Surge Arrester with External Gap a Type
Yh10W-33, Sharp Head 33kv 10ka Surge Arrester
Polymer Housed Metal Oxide Surge Arrester Without Gaps
Popular Surge Arresters Products
Electrical Product 30kv Surge Protective Device
Indonesia Silicone Rubber 66kv Surge Arresters with Electrical Terminals
10ka 12kv Silicon Rubber Housed Metal Oxide Gapless Surge Arrester
36kv/10ka Yh10W-36kv Polymeric Surge Arrester
Power Station Transformer Arrester/ Line Type Lightning Arrestors
High Voltage Composite/ Ceramic Housed Lightning Arrester 15kv
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters