Medium Voltage Polymeric Housed Lightning Protection Protector
Medium Voltage Polymeric Housed Lightning Protection Protector image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
| Type | YH10W5-15/41.2 | 4/10µS High current impulse kA | 100 |
| Rated voltage———kV | 15 | Lightning impulse withstand kV | 110 |
| MCOV —————-kV | 12.7 | Power frequency voltage withstand(dry/wet)kV | 28 |
| Nominal Current——-kA | 10 | 0.1S TOV————–kV | 18 |
| Residual voltage of steep impulse—-at 5kA(kV) | 44.5 | 1S TOV—————-kV | 17.25 |
| 8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 41.2 | 10S TOV—————kV | 16.5 |
| Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 31.5 | 1200S TOV————-kV | 15 |
| 1mA D.C reference voltage (kV) | 21.2 | Creepage distance —-mm | 500 |
| Line discharge level | 1 | Material employed in series non-linear resistor | Zinc Oxide |
| 2mS long duration impulse current A | 400 | Material of housing | silicone rubber |
Working condition:
| Environment temperature: -40–+40 degree | |||||||
| altitude:<1000m | |||||||
| 48HZ<Rated frequency<62HZ | |||||||
| Power frequency voltage should not be more than continuous running voltage | |||||||
| Max wind speed should be less than 35m/s | |||||||
| Earthquake intensity should be less than 7 degree | |||||||
| If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Medium Voltage Polymeric Housed Lightning Protection Protector manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Kema 11kv Surge Arrester Zinc Oxide Lightning Arrester
Jw-126 Outdoor Mounted Three - Poles High Voltage Isolating Switch
Wholesale Price Surge Arrester Varistor Lightning Arrester Resistor
Hpd 33-36kv Fuse Cutout for Power Transmission
Silicon Rubber Polymer Housing Metal Oxide Surge Arrester Without Gaps
Electronic Components Low Voltage Surge Arrester Over Current Lightning Arrester
Popular Lightning Arrester Products
120kv High Voltage Line Silicon Housing Lightning Diverter with External Gap
High Voltage Electrical Product Silicone Porcelain Surge Arrester 36kv to 110kv
12kv Silicon Type Surge Arrester Cma10W-12-1
33kv Double Pole Drop out Fuse
Popular Surge Arrester Products
Porcelain Arrester Bushing 12kv
33kv Double Pole Drop out Fuse
Composite Surge Arrester/Lightning Arrester/Polymer Surge Arreter
20kv Porcelain Fuse Cutout Insulator
Cutting Machine Acetylene Gas Flashback Arrester
Popular Surge Arresters Products
Lightning Arrestor High Voltage Metal Oxide Station Surge Arrestor
0.25~765kv Polymer Silicone Porcelain Housed Gapless Lightning Arresters
Rated Current 5ka Polymeric Housed Station Class Surge Diverters with Counter
Hv Metal Oxide Porcelain Lighting Arrester with Garding Ring
110kv/10ka Metal-Oxide Polymeric Surge Arrester
Extra High Voltage Porcelain Moa Zinc Oxide Lightning Arresters
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters
