Rated Voltage 100kv 110kv 120kv Transmission Line Type ZnO Lightning Diverter
Rated Voltage 100kv 110kv 120kv Transmission Line Type ZnO Lightning Diverter image
Get Latest Price Request a quote
Quick Details
Product Details
100kV 110kV 120kV transmission line type polymeric lightning protector
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
| Type | Nominal System Voltage | Rated Voltage | Minimum Reference Voltage under 1 mA DC | Residual voltages at steep impulse current | Residual voltages at lightning impulse | 1.2/50 Impulse Discharge Voltage kV< =(+) | Power Frequency Withstand Voltage | 4/10 μ S High Current (KA) | 2mS current /A | ||
| 5kA | 10kA | 5kA | 10kA | ||||||||
| YH10CX-90/260 | 110 | 90 | 130 | 292 | 260 | 525 | 185 | 100 | 600 | ||
| YH10CX-96/280 | 110 | 96 | 140 | 314 | 280 | 525 | 185 | 100 | 600 | ||
| YH10CX-102/296 | 110 | 102 | 148 | 332 | 296 | 525 | 185 | 100 | 600 | ||
| YH10CX-120/320 | 132 | 120 | 170 | 365 | 320 | 535 | 210 | 100 | 850 | ||
Working condition:
| Environment temperature: -40–+40 degree | |||||||
| altitude:<1000m | |||||||
| 48HZ<Rated frequency<62HZ | |||||||
| Power frequency voltage should not be more than continuous running voltage | |||||||
| Max wind speed should be less than 35m/s | |||||||
| Earthquake intensity should be less than 7 degree | |||||||
| If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Rated Voltage 100kv 110kv 120kv Transmission Line Type ZnO Lightning Diverter manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
36kv Polymer Housed Line Lightning Arrestor
Motor Operating Mechanism Boxes for Disconnector
D35 Metal Zinc Oxide Resistance for Surge Arrester
Ceramic Polymeric 36kv Lightning Arrester for Lightning Protection
Substation Surge Protective Lightning Arrester for Lightning Protection System
Popular Lightning Arrester Products
24kv Moa Surge Arrester/Composite Lightning Arrester
Hy5w-3.8/17 Zinc-Oxide Arrester
120 Kv, 10ka, 1pH, Suger Arrester
12kv Silicon Type Surge Arrester CMA5W-12
Insulator Lightning Surge Arrester
Polymeric Housed Metal-Oxide 12kv Surge Arrester Without Gaps (YH5W-3)
Popular Surge Arrester Products
110kv Silicon Type Surge Arrester CMA5WX-108/309
Ruitian Brand 12kv Line Types of Lightning Arrester
Polymer Fuse Cutout, Drop out Fuses 50kv 100A
(Y10W-66) Porcelain Housed Metal-Oxide Surge Arrester
Yh10W-192, 192kv 10ka Surge Arrester
Popular Surge Arresters Products
Polymeric Housed Zinc Oxide Lightning Surge Arresters Series
OEM/ODM Power Distribution Equipment 110kv Lightning Arrester with Kema Report
Medium Voltage 27kv 5ka 10ka Metal Oxide Silicone Surge Arrester
Medium Voltage Polymeric Housed Lightning Protection Protector
Nominal Current 5ka Silicone Polymeric Housed Lightening Arrester
Line Discharge Level 1 Porcelain Arrester Lightening Arrester with External Gap
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters