220kv Substation All Types of Zinc-Oxide Lighting Arrester up to 500kv
220kv Substation All Types of Zinc-Oxide Lighting Arrester up to 500kv image
Get Latest Price Request a quote
Quick Details
Product Details
Main features:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
| Type | Y10W5-66/176 |
| Rated voltage———kV | 66 |
| MCOV —————-kV | 52.8 |
| Nominal Current——-kA | 10 |
| Residual voltage of steep impulse—-at 5kA(kV) | 221 |
| 8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 178 |
| Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 137 |
| 1mA D.C reference voltage (kV) | 96 |
| Line discharge level | 1 |
| 2mS long duration impulse current A | 400 |
| 4/10µS High current impulse kA | 100 |
| Lightning impulse withstand kV | 325 |
| Power frequency voltage withstand(dry/wet)kV | 140 |
| 0.1S TOV————–kV | 79.2 |
| 1S TOV—————-kV | 75.9 |
| 10S TOV—————kV | 72.6 |
| 1200S TOV————-kV | 66 |
| Creepage distance —-mm | 2500 |
| Material employed in series non-linear resistor | Zinc Oxide |
Working condition:
| Environment temperature: -40–+40 degree | |||||||
| altitude:<1000m | |||||||
| 48HZ<Rated frequency<62HZ | |||||||
| Power frequency voltage should not be more than continuous running voltage | |||||||
| Max wind speed should be less than 35m/s | |||||||
| Earthquake intensity should be less than 7 degree | |||||||
| If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China 220kv Substation All Types of Zinc-Oxide Lighting Arrester up to 500kv manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
High Quality Lightning Sound Arrester
Kema Low Voltage Metal Oxide Gapless Surge Arrester Lightning
Surge Arrester 10ka, 12kv Polymer Housded
6kv 5ka Outdoor Mv Surge Arrester
Zinc Oxide Arrester/Substation Surge Arrestor
Popular Lightning Arrestor Products
220kv Station Polymer Surge Arrester/Composite Lightning Arrestor
35kv Porcelain Housed Gapless Metal Oxidelightning Arrester (Y5WZ5-51/134)
Transformer Surge Protection Lightning Arrestor
Outdoor Rated Voltage 12-36kv porcelain Polymer Lightning Protecting Arrester
Hangzhou Fuyang 220kv Electrical Supplies Polymeric Gapless Lightning Arrestor
OEM/ODM Power Distribution Equipment 110kv Lightning Arrester with Kema Report
Popular Surge Arrester Products
Yh10W-6, 6kv 10ka Surge Arrester
(YH10W-66) Polymeric Housed Metal-Oxide Surge Arrester
11kv-33kv Outdoor High Voltage Porcelain Lightning Arrester
Moa/Metal Oxide Lightning Arrester /Metal Oxide Surge Arrester
Popular Surge Arresters Products
110kv/10ka Metal-Oxide Polymeric Surge Arrester
Kema Tested Electrical Equipments Rated Voltage 102kv Polymeric Surge Diverters
Innvoation Electrical Station Class Porcelain Surge Arrestors
Outdoor Electric Line Discharge Level 1 to 5 Porcelain Lighting Arrester 110kv
24kv 10ka Polymer Housed Surge Arrester
24kv/10ka Polymeric Housed Zinc Oxide Surge Arrester
Tags: hzyddq, Lightning Arrestor, Surge Arrester, Surge Arresters
