Fuse 60 AMPS- T

China 
                        Fuse 60 AMPS- T
                      manufacture and supplier

Fuse 60 AMPS- T image

Get Latest Price Request a quote

Quick Details

Fuse 60 AMPS- T

ISO9001-2000

Conventional Circuit Breaker

Circuit Breaker

3

MCCB

Fixed

Air

Normal Type Circuit Breaker

Manual Type

Low Voltage Circuit Breakers

85362000

Product Details

 MCCB, RCCB, ELCB

Rated current
 
63A,100A,125A,160A,200A, 300A,400A,630A and 800A
 
No. of poles per phase
 
1
 
Rated service short circuit breaking capacity(kA)
 
Min. 18kA
 

 

MCB, MCCB, RCCB, and ELCB are circuit breakers but all of them are designed for serving a specific purpose. Before knowing about the difference among all, let’s get to know about them a little bit.
 

MCB

MCB stands for Miniature Circuit Breaker. It automatically switches OFF electrical circuit during any abnormal condition in the electrical network such as overload & short circuitconditions. However, fuse may sense these conditions but it has to be replaced though MCB can be reset. The MCB is an electromechanical device which guards the electric wires &electrical load from overcurrent so as to avoid any kind of fire or electrical hazards. Handling MCB is quite safer and it quickly restores the supply.When it comes to house applications, MCB is the most preferred choice for overload and short circuit protection. MCB can be reset very fast & don’t have any maintenance cost. MCB works on bi-metal respective principle which provides protection against overload current&solenoidshort circuit current.
 

MCCB

MCCB stands for Molded Case Circuit Breaker. It is another type of electrical protection device which is used when load current exceeds the limit of a miniature circuit breaker. The MCCB provides protection against overload, short circuit faults and is also used for switching the circuits. It can be used for higher current rating and fault level even in domestic applications. The wide current ratings and high breaking capacity in MCCB find their use in industrial applications. MCCB can be used for protection of capacitor bank, generator protection and main electric feeder distribution. It offers adequate protection whenever an application requires discrimination, adjustable overload setting or earth fault protection.

The fuses mention in the table below will be exposed to the following environmental conditions:
   Maximum altitude above mean sea level less than 1,000 m;
   Maximum ambient air temperature 400C;
   Maximum daily average ambient air temperature 300C;
   Minimum ambient temperature150C; and
   Maximum relative humidity 100%.

Requirements
   The fuse-links and fuse-end fittings shall be of the following ratings (table below) and      comply with the IEEE Std C37.4 -2016 or an equivalent international standard. The fuse- links shall be used primarily for protection of distribution transformers, laterals and sub-  laterals.
   The fuse links shall be capable of withstanding 125% ofthe transformer rated full load current continuously and periodic over-loads up to 150% ofthe transformer rated full   load current.

 The current-time characteristics of the fuse-links offered shall be submitted with the tender
   Markings shall be provided on the fuse-links in accordance with ANSI/IEEE Standards.

RCCB stands for Residual Current Circuit Breaker. This residual current device is basically an electrical wiring device that disconnects the circuit whenever there is leakage of current flow through the Human body or the current is not balanced between the phaseconductor. It is the safest device to detect and trip against electrical leakage currents, thus ensure protection against electric shock caused by direct contacts. RCCB is generally used in series with an MCB which protects them from over current and short circuit current. Both phase and neutral wires are connected through a RCCB device. These are an extremely effective form of shock protection&widely used for protection from a leakage current of 30,100 & 300mA. It is essential lifesaving equipment used to protect the human body from electrical and is mandatory in many states for domestic installation.

ELCB stands for Earth Leakage Circuit Breaker. They have the same function as RCCB but are voltage sensor devise. However, this is an old technology & is not in common use. RCCB being a current sensitive device have a better advantage over ELCB as under:

Difference between RCCB and ELCB

View More  

Not exactly what you want?

Post Sourcing Request

Hot Searches

Electronic Circuit Breaker
Current Circuit Breaker
Circuit Breaker Case
Vacuum Circuit Breaker
Mini Circuit Breaker
Circuit Breaker Box
View More 

We are China Fuse 60 AMPS- T manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Circuit Breaker Products

33kv Polymeric Lightning Arresters/Surge Arrester

Vsg-12 1600A Medium Voltage Fixed Type Vacuum Breaker 12kv

Indoor 10kv 12kv Mv Withdrawable Vacuum Circuit Breaker for High Voltage Switch Cabinet

Tubular Bus-Bar Supports Type Mgg2

High Voltage Gis Circuit Breaker for Gas Insulated Switchgear

Outdoor Sf6 Gas Circuit Breaker (66kV/132kV)

Popular jgtrade1 Products

Tubular Bus-Bar Joints Type Mj/W, Outside

Double Straps Type Pd

Herringbone Platform Ladder

Support Type Single Flexible Terminal Connectors for Tubular Bus-Bar Type Msz, Horizontal Type

36kv Expulsion Fuse Element

Straight Joint Waterproof Junction Box Selection Table

Popular Miniature Circuit Breaker Products

Zw32-12 Outdoor Use High Voltage Vacuum Circuit Breaker

Universal Clamp on Safety Plastic Lockout Devices MCCB Lock

Post Insulator High Voltage Electrical Apparatus

Zn 28-12 Series Vacuum Circuit Breaker

Miniature Circuit Breaker MCB MCCB

Circuit Breaker with 660V Rated Insulating Voltage

Popular Products

Fn12-12 Series Indoor Use High Voltage Load Switch

Liyond 35kv Floor Mounted Vacuum Circuit Breaker

400 AMP 3 Pole Automatic Circuit Breaker with Overload, Short Circuit, Overvoltage Protection MCCB

Support Type Tubular Bus-Bar Flexible Fittings Type Mgsz

Vsm-12 Handcart Type Permanent Magnet Mechanism Indoor Vacuum Circuit Breaker for 12kv Vcb

Gw8-12g/630-20 Outdoor Use, Pole Mounted Dry Type Vacuum Circuit Breaker

Tags: , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION