Clamp, Hot Line

China 
                        Clamp, Hot Line
                      manufacture and supplier

Clamp, Hot Line image

Get Latest Price Request a quote

Quick Details

Clamp, Hot Line

IEC IEEE

Fuse Link

T K

Circle

High Voltage

Distribution

High

OEIpower

Cartons Pallets Wooden Case

IEC282-2 IEEEc37-41

China Nanyang

85351000

Product Details

CUT-OUT

Gama 20 kV a 36 kV

– Circuito Principal 200 A
– Ith 8 kA.
– Montaje Vertical
– Tubo Fusible de 100 A
– Norma CEI 282-2

– Tubo Fusible compatible con los
estándar norteamericanos.
– Este modelo permite el montaje
de la Autoválvula directamente
sobre la escuadra de fijación.
– Eslabones fusible:
de 2 Amp. a 100 Amp.
– Porcelana de color gris, efecto
Antivandálico.

— Montaje sencillo gracias a sus
tornillos de fijación anti-giro.
– No es necesaria ninguna
herramienta para cambiar el
eslabón

La base cortacircuitos en "V" monta aisladores de columna con
armaduras metálicas externas y línea de fuga en función de los niveles
de contaminación I-III-IV asignados.
Su diseño permite el accionamiento por pértiga desde una posición mas
cómoda para la maniobra, al conseguir un ángulo de 45º con respecto a
la base de sujección.
Incorpora un tubo fusible con capacidad para eslabones de hasta 100A
, y es totalmente intercambiable con los modelos de una columna y
modelos de otros fabricantes.
El interior del tubo portafusible está constituido por un recubrimiento
vegetal lo que le confiere un poder de extinción superior a otros
modelos (según fabricante).

El Seccionalizador en "V" monta aisladores de columna con
armaduras metálicas externas y línea de fuga en función de los niveles
de contaminación I-III-IV asignados.
Su diseño permite el accionamiento por pértiga desde una posición mas
cómoda para la maniobra, al conseguir un ángulo de 45º con respecto a
la base de sujección.
Gama:
15 , 24 y 36 kV
12 – 25 – 40 – 63 -100 – 140 A
Número de Defectos: 1 , 2 (Estándar) , 3.
Tiempo de Regeneración : Min. 30s.

Principales Características :
Dispositivo Autoalimentado. Utilización conjunta con Interruptores automáticos.
Importante reducción en los costes derivados de mano de obra y sustitución de fusible de los Cut-Out
convencionales derivados de fallos transitorios, ocasionados por tormentas eléctricas , accidentes
vegetales , etc…
Ausencia de Arcos y desgaste en los contactos.
Reutilización del equipo tras su rearme manual y acoplamiento en su base.

TYPE "OEI" "PRW" STANDARD CUTOUT DISTRIBUTION TECHNICAL SPECIFICATION
The Fuse Cutout type DHE was developed to operate in overhead distribution systems rated at 12-15 kV and 15-27,kV or 27-38 kV grounded systems with 100 or 200 A nominal currents.
Especially designed to protect transformers, capacitors, cables or lines.
It is robust construction, made of rigorously tested material, will interrupt all faults under the
most severe conditions, maintaining mechanical and electric characteristics.
The inserts, hardware and structural bolts and nuts are made from heavy galvanized steel.
The Fuse Cutout type OEI PRW can be applied on all three-phase system rated at or below the maximum operational rating of the cutout. In highly polluted environments or environments with high levels of salinity, a cutout may be used with a higher nominal rating than
that of the system where it is being installed, where the insulator will have a greater leakage distance to ground, allowing for
increased safety against discharge. For an even better protection against abrasions, the hardware may be supplied in stainless
 For Aluminum and ACSR conductor.
   Designed for standard "hot stick" application.
   Material: Body and Keeper  Aluminum Alloy
   Eyebolt  Bronze Alloy  Tin Plated
   Eye stem  Bronze Alloy, Forged or Stainless Steel
   Spring (on eye stem)  Stainless Steel
 

Item
#
Main Line Tap Plating Conductor Range (AWG or kcmil) Dimension  Inches (mm) Tap
Nut
Approx.
Wt.
Lbs (Kg)
Main Tap
ACC ACSR AAC/CU ACSR L H
104 AL AL/CU Tin
plated
0.502  1.031  (12.78  26.24) 0.198  0.703 (5.03  17.89) 1.81
(46)
7.31  (186) ¾   (19) 0.98
(0.45)

steel. The fuse cutout type OEI PRW has attachment hooks in aluminum.
The Fuseholder has a stainless steel flipper, which associated with a spring doesn’t allow the fuse link to be subject to traction
forces of over 3 Kgf, especially during closing. This me chanism also allows for high speed fuse link separation. The fuse cutout
type OEI PRW allows for the insertion of the fuse tube in a precise man ner and always in perfect alignment, due to the large distance
between the grunion pocket. Lower contact, silver-to-silver, provide du el current path, independent of hinge pivot. Stainless-steel
back-up springs prevent arcing when tube rises in hinge during recoil. The fuse cutout type OEI PRW may be transformed into a DICONNECT up to 300 A, by simply changing the fuse tube for an electrolytic copper blade.
The DHE Fuse Cutouts conform to ANSI and IEC standards, with independent tests performed At:
CPRI Always use quality fuse links. Only they can assure excellent performance.

View More  

Not exactly what you want?

Post Sourcing Request

Hot Searches

Fuse
Protection Fuse
Fuse Box
Fast Fuse
Fuse Out
Fuse Unit
View More 

We are China Clamp, Hot Line manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Arc Chute Type Products

Outdoor Single Pole Fused Recloser by-Pass Switches24kv

Bolt & Nut, Machine 5/8" X 14" Galv

Expulsion Fuse Fuse-Link 38kv

Expulsion Fuse Fuse-Link 33kv

Anchor, No-Wrench 10in X 96intripleye- Chance 10148

High-Voltage Disconnector Switch 36kv

Popular Interrupter Products

'high-Voltage Limit-Current Fuse for Protection Oil-Immersed Type Transformer

Switch Disconnector Fuse Holder, 21 Kv - 100 AMP, Without Arc Chute

12kv, 24kv & 36kv Fuse Cutouts Porcelain

15kv 100A-200A Electrical Porcelain Drop-out Fuse Cutout

11kv 12kv High Voltage Polymer Dropout Expulsion Fuse Cutout

Dideron Rope

Popular jgtrade1 Products

Signboard with Support

M16X260 Bolts &Nuts

Lightning Arrestors Yh5w-9

Cowhide Split Leather Welding Gloves

Switch Disconnector Fuse Holder, 15 Kv - 200 AMP, Without Arc Chute

Bolt Guardacabo Eye Angular 5/8 "X 12"

Popular Loadbreak Cutout Products

Best Price36kv 100A Ceramic Types Drop out Fuses Cutout/Cut out Fuse

Expulsion Fuse-Cut out 10kv

Outdoor Single Pole Fused Recloser by-Pass Switches 72.5kv

Coupling Pipe for Clamp (for GSW truss)

Expulsion Fuse Fuse-Link 38kv

Outdoor Single Pole Fused Recloser by-Pass Switches24kv 600A

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION