0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
| Type: |
Y5W5-108/259 |
||
| Rated voltage———kV | 108 | 4/10µS High current impulse kA | 100 |
| MCOV —————-kV | 86 | Lightning impulse withstand kV | 550 |
| Nominal Current——-kA | 5 | Power frequency voltage withstand(dry/wet)kV | 230 |
| Residual voltage of steep impulse—-at 5kA(kV) | 339 | 0.1S TOV————–kV | 129.6 |
| 8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 281 | 1S TOV—————-kV | 124.2 |
| Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 220 | 10S TOV—————kV | 118.8 |
| 1mA D.C reference voltage (kV) | 157 | 1200S TOV————-kV | 108 |
| Line discharge level | 2 | Creepage distance —-mm | 3906 |
| 2mS long duration impulse current A | 600 | Material employed in series non-linear resistor | Zinc Oxide |
Working condition:
| Environment temperature: -40–+40 degree | |||||||
| altitude:<1000m | |||||||
| 48HZ<Rated frequency<62HZ | |||||||
| Power frequency voltage should not be more than continuous running voltage | |||||||
| Max wind speed should be less than 35m/s | |||||||
| Earthquake intensity should be less than 7 degree | |||||||
| If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Hv Ceramic Housed Metal Oxide Arrester Lightning 110kv manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Porcelain Types of Lightning Arrester with Kema Type Test Report
Electrical Transformer Type Metal Oxide Gapless Surge Arrester
Zinc Oxide Grey Surge Arrestor (S. A)
Silicon Rubber Suspension Insulator
Factory Price Current Ceramic ZnO Metal Oxide Gapless Surge Arrester
Metal Oxide Gapless Lightning Arrester
Popular Lightning Arrester Products
30kv Silicone Polymer Housing Composite Metal Oxide Lightning Arrester
Polymer Housed Metal Oxide Lightning Arrester Without Gaps
24kv Polymeric Housed Metal Oxide Lightning Arrester
Porcelain Housed Lighting Arrester for Power Station
Yh10W-48, 48kv- 10ka Surge Arrester
Popular Surge Arrester Products
Xirui 220kv 216kv High Voltage Porcelain Surge Lightning Arrester
15kv Polymer Metal Oxide Ceramic Surge Arrester
Xirui Factory Bulk 6kv 10ka Metal Oxide Silicone Rubber Gapless Lightning Arrester
High Voltage Electric Silicone Porcelain Surge Arrester 36kv to 110kv
High Voltage Transmission Equipment Gapless Composite Porcelain Surge Arrester
Popular Surge Arresters Products
Innvoation Electrical Station Class Porcelain Surge Arrestors
Factory-Made High Discharge Capacity Housed Metal-Oxide Electrical Surge Protector
Rated Voltage 60kv Line Type Polymer Housing Lightning Arrestor Without Gaps
Indonesia Silicone Rubber 66kv Surge Arresters with Electrical Terminals
Outdoor Line Class Brace-Type Surge Arrester (HY5WBG-17/50)
245kv-362kv AC System Gapless Metal Oxide Arrester with Polymer Housed
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters