Nominal System Voltage 110kv Line Composite Polymeric ZnO Arresters
Nominal System Voltage 110kv Line Composite Polymeric ZnO Arresters image
Get Latest Price Request a quote
Quick Details
Product Details
hv transmission line composite polymeric silicone zno arresters
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
Type | Nominal System Voltage | Rated Voltage | Minimum Reference Voltage under 1 mA DC | Residual voltages at steep impulse current | Residual voltages at lightning impulse | 1.2/50 Impulse Discharge Voltage kV< =(+) | Power Frequency Withstand Voltage | 4/10 μ S High Current (KA) | 2mS current /A | ||
5kA | 10kA | 5kA | 10kA | ||||||||
YH10CX-90/260 | 110 | 90 | 130 | 292 | 260 | 525 | 185 | 100 | 600 | ||
YH10CX-96/280 | 110 | 96 | 140 | 314 | 280 | 525 | 185 | 100 | 600 | ||
YH10CX-102/296 | 110 | 102 | 148 | 332 | 296 | 525 | 185 | 100 | 600 | ||
YH10CX-120/320 | 132 | 120 | 170 | 365 | 320 | 535 | 210 | 100 | 850 |
Working condition:
Environment temperature: -40–+40 degree | |||||||
altitude:<1000m | |||||||
48HZ<Rated frequency<62HZ | |||||||
Power frequency voltage should not be more than continuous running voltage | |||||||
Max wind speed should be less than 35m/s | |||||||
Earthquake intensity should be less than 7 degree | |||||||
If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Nominal System Voltage 110kv Line Composite Polymeric ZnO Arresters manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Class 1electric Outdoor 27kv/5ka Polymer Type Lightning Arrester Price
Electrical Items Price List 20kv Ceramic Porcelain Fuse Cut out
Electric Components MOV Varistor ZnO Varisotr
Power Operating Mechanism for Disconnector
Fuyang SMD Resistor Voltage Dependent Resistor
Popular Lightning Arrester Products
10ka Surge Arrester Over Voltage Protector Hy10W-11kv
12kv -36 Kv Polymer Housed Gapless Surge Arrester
24kv High Quality Oxide Zinc Lightning Arrester for Substation
Metal-Oxide Lightning Arrester, Surge Arrester Yh5w, Yh10W
Popular Surge Arrester Products
11kv Silicone Rubber Lightning Arrester
15kv Metal-Oxide Surge Arrester for Overvoltage Protection
Polymer Fuse Cutout, Drop out Fuses 45 Kv 300A
Rated Voltage 21kv Mcov 17kv Creepage Distance 662mm Arrestor with Polymer Housed
Metal-Oxide Lightning Arrester, Surge Arrester Yh5w, Yh10W
Popular Surge Arresters Products
10ka Power Station Type Ceramic ZnO Surge Diverters with Silicone Housed
3kv Polymeric Housed Zinc Oxide Lightning Arresters
5ka 3-36kv Polymeric Housed Zinc Oxide Lightning Arresters Without Gaps
33kv Hv Polymeric Housed Silicone ZnO Gapless Lightning Arrestor
Kema Lighting Arrest Surge Lightning Arrester for Substation
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters