XLPE Insulated Copper Conductor Power Cable 300sqmm
XLPE Insulated Copper Conductor Power Cable 300sqmm image
Get Latest Price Request a quote
Quick Details
Product Details
Application:
It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.
Construction:
Conductor: Copper (or Aluminium)
Insulation: XLPE
Filler: Non-hygroscopic Polypropylene(PP)
Binder Tape: Non-woven fabric
Inner Covering: PVC
Metallic Armour: Galvanized Steel Wire Armour(SWA)
Non-magnetic Steel Wire Armour(only for single core)
Aluminium Wire Armoured(AWA, only for single core)
Outer Sheath: PVC (or PE)
Standards:
The products are mainly complying with IEC 60502 standard, also can be produced according to OEM requirements and other standards, such as BS standard, DIN standard, ASTM standard, etc.
Voltage grade is up to 35kv, cross-section area can be up to 400 sqmm (copper or alumimum conductor). Conductor long-time operating temperature is 90°C. In short circuit, conductor highest temperature should be not more than 250°C
Using features:
1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV.
2. No. of core: Single-core, Three-core.
3. The highest allowed operating temperature of conductor for long-term working is 90°C. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250°C.
4. D.C Resistance of the conductor complies with the stipulations of GB/T3956-1997.
5. The environment temperature should be no lower than 0°C when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit. The Min. Bending radius of three-core cable should be no smaller than 12 times of cable outer diameter.
7. Working Frequency Voltage Test:.
For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture.
For cable with Uo of 3.6Kv~18kV: 3.5Uo/5min without puncture.
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
|
Type |
Description |
Number of cores |
Nominal cross section of conductor |
|
YJV32 |
CU/XLPE/SWA/PVC Power Cable |
1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm2 |
|
YJLV32 |
AL/XLPE/SWA/PVC Power Cable |
||
|
YJV72 |
CU/XLPE/Non-magnetic SWA or AWA/PVC Power Cable |
1 |
1.5~1000mm2 |
|
YJLV72 |
AL/XLPE/Non-magnetic SWA or AWA/PVC Power Cable |
||
|
YJV33 |
CU/XLPE/SWA/PE Power Cable |
1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm2 |
|
YJLV33 |
AL/XLPE/SWA/PE Power Cable |
||
|
Z-YJV32 |
CU/XLPE/SWA Flame-retardant Power Cable |
1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm2 |
|
Z-YJLV32 |
AL/XLPE/SWA Flame-retardant Power Cable |
||
|
WDZ-YJY33 |
CU/XLPE/SWA Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) Flame-retardant Power Cable |
1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm2 |
|
WDZ-YJLY33 |
AL/XLPE/SWA Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) Flame-retardant Power Cable |
||
|
N-YJV32 |
CU/XLPE/SWA Fire-resistant Power Cable |
1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm2 |
|
Type |
Name |
Application |
|
|
Cu conducto |
Al Conductor |
||
|
YJV |
YJLV |
XLPE insulated, PVC or PE sheathed power cable |
For laying indoor, tunnel, channel and underground. Unable to bear external mechanical force during laid. |
|
YJY |
YJLV |
||
|
YJV22 |
YJLV22 |
XLPE insulated, steel tape armoured, PVC or PE sheathed power cable |
For laying indoor, tunnel, channel and underground. Able to bear external mechanical force, but unable to bear large pulling force. |
|
YJV23 |
YJLY23 |
||
|
YJV32 |
YJLV32 |
XLPE insulated, fine steel wire armoured, PVC or PE sheathed power cable |
For laying in shaft with large difference of level. Able to bear external mechanical force ,and moderate pulling force. |
|
YJV42 |
YJLV42 |
XLPE insulated, thick steel armoured, PVC or PE sheathed power cable |
For laying in shaft with large difference of level. Able to bear external mechanical force ,and moderate pulling force. |
We are China XLPE Insulated Copper Conductor Power Cable 300sqmm manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Electrical Cable Products
1X50mm2 Copper Control cable XLPE Insulation PVC Sheahted Power Cable 0.6/1kV
Low Voltage Unarmored Yjv Cable 0.6/1kv
LV PVC Power Cable Copper Conductor
UL Standard Thhn Thwn Electric Wires and Cables
450/750V 1core X 6sqmm Copper Conductor PVC Insulated Electrical Wire for Home and Office
Bt Twisted Cable 2X25mm2 NFC Standard
Popular jsgroup Products
Aluminum Wire Stranded Conductor ASTM Standard
Factory Supply Low Voltage Rubber Sheathed Welding Cable for Sale
ABC Duplex Triplex Aerial Bundled Cable 25 50 mm
Aerial Bundled Cable 0.6/1kv Voltage Overhead Electric Cable
0.6/1kv XLPE Insulation Five Core 16mm 25mm 50mm Aluminum Core Aerial Bundle Cable
Stainless Steel Wire Strand for Overhead Bare Cable
Popular Power Cable Products
cUL and CSA List Electric Aluminum Armour Power Cable Teck90 Cable Acwu AC90 Cable 600V 1000V
XLPE Insulated Steel Tape Armoured Power Cable (10KV3-95) Photos & Pictures
0.6/1kv Cu Conductor PVC Insulation Steel Wire Tape Power Cable
2+1, 3+1, 4+1 PVC Ren Da Armoured Aluminum Building Cable
Low Smoke Halogen Free XLPE Insulated PVC Sheathed Transmission and Distribution Power Cable
Popular Wire Cable Products
Galvanized Steel Wire Strand (Guy wire, stay wire)
High Quality French Standard ABC Cable Widely Used in Rural Electrification
IEC Standard ABC Overhead Cable
Aluminum Conductor Aerial Bundle Electrical Cable PVC Insulated PE Insulation Overhead ABC Cable
XLPE/PE/PVC Insulated Aluminum Cable 2*70+70sqmm Triplex Service Drop Cable ABC Cable
Tags: Electrical Cable, jsgroup, Power Cable, Wire Cable