Aluminum Alloy Steel Reinforced Overhead Power Transmission Line ABC Cable
Aluminum Alloy Steel Reinforced Overhead Power Transmission Line ABC Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Tel: 0086 532 85611663 Phone: 0086 15192706553
__________________________________________________________________________________________
Product Description
ACAR Aluminum Conductor Alloy Reinforced Aerial Bundle Cable
1. Specification
JL All Aluminum Conductor Basic parameter | ||
Specification | Outer Diameter of Cable | Approximate weight |
10 | 4.05 | 27.95 |
16 | 5.13 | 45.00 |
25 | 6.39 | 69.59 |
35 | 7.50 | 96.14 |
40 | 8.10 | 112.08 |
50 | 9.00 | 138.35 |
63 | 10.20 | 176.64 |
70 | 10.80 | 199.28 |
95 | 12.50 | 265.80 |
100 | 13.0 | 279.49 |
120 | 14.3 | 338.18 |
125 | 14.5 | 349.36 |
150 | 15.8 | 413.65 |
160 | 16.4 | 447.18 |
185 | 17.5 | 511.47 |
200 | 18.3 | 558.98 |
210 | 18.8 | 586.93 |
240 | 20.0 | 667.98 |
250 | 20.5 | 698.73 |
300 | 22.4 | 832.88 |
315 | 23.0 | 880.39 |
400 | 26.0 | 1117.96 |
450 | 27.6 | 1260.50 |
500 | 29.1 | 1405.84 |
560 | 30.7 | 1565.15 |
630 | 32.7 | 1763.58 |
710 | 34.7 | 1984.38 |
800 | 36.8 | 2238.72 |
JL/G1A JL/G2A JL/G3A JL1/G1A JL1/G2A JL1/G3A JL2/G1A JL2/G2A JL2/G3A &JL3/G1A JL3/G2A JL3/G3A Aluminum Conductor Steel Reinforced Basic parameter |
|||||
Specification | Outer Diameter of Cable | Approximate weight | Specification | Outer Diameter of Cable | Approximate weight |
10/2 | 4.50 | 43.68 | 240/30 | 21.6 | 932.18 |
16/3 | 5.55 | 66.23 | 240/40 | 21.7 | 975.04 |
25/4 | 6.90 | 102.35 | 240/55 | 22.4 | 1117.98 |
35/6 | 8.16 | 143.40 | 250/25 | 21.5 | 892.12 |
40/6 | 8.73 | 164.01 | 250/40 | 22.2 | 1020.00 |
50/8 | 9.60 | 198.46 | 300/15 | 23.0 | 950.86 |
50/30 | 11.6 | 375.35 | 300/20 | 23.1 | 995.25 |
65/10 | 11.0 | 259.24 | 300/25 | 23.8 | 1069.16 |
70/10 | 11.4 | 279.25 | 300/40 | 23.9 | 1145.53 |
70/40 | 13.6 | 516.07 | 300/50 | 24.3 | 1223.68 |
95/15 | 13.6 | 384.61 | 300/70 | 25.2 | 1415.26 |
95/20 | 13.9 | 414.19 | 315/22 | 23.9 | 1055.27 |
95/55 | 16.0 | 714.12 | 400/20 | 26.9 | 1299.71 |
100/17 | 13.8 | 411.31 | 400/25 | 26.6 | 1309.52 |
120/7 | 14.5 | 384.69 | 400/35 | 26.8 | 1364.35 |
120/20 | 15.1 | 472.61 | 400/50 | 27.6 | 1526.85 |
120/25 | 15.7 | 532.00 | 400/65 | 28.0 | 1629.04 |
120/70 | 18.0 | 903.79 | 400/95 | 29.1 | 1876.79 |
125/7 | 14.9 | 404.07 | 450/30 | 28.6 | 1503.20 |
125/20 | 15.6 | 588.54 | 450/60 | 29.3 | 1721.49 |
150/8 | 16.0 | 468.73 | 500/35 | 30.1 | 1670.57 |
150/20 | 16.7 | 556.46 | 500/45 | 30.0 | 1706.92 |
150/25 | 17.1 | 607.47 | 500/65 | 30.9 | 1905.37 |
150/35 | 17.5 | 682.39 | 560/40 | 31.8 | 1869.84 |
160/9 | 16.8 | 517.20 | 560/70 | 32.7 | 2122.01 |
185/10 | 18.0 | 591.98 | 630/45 | 33.8 | 2100.58 |
185/25 | 18.9 | 713.67 | 630/55 | 34.3 | 2233.15 |
185/30 | 18.9 | 739.53 | 630/80 | 34.7 | 2386.32 |
185/45 | 19.6 | 857.27 | 710/50 | 35.9 | 2369.95 |
200/11 | 18.8 | 646.60 | 710/90 | 36.8 | 2688.85 |
210/10 | 19.0 | 659.36 | 720/50 | 36.2 | 2421.77 |
210/25 | 20.0 | 798.05 | 800/55 | 38.4 | 2719.46 |
210/35 | 20.4 | 864.06 | 800/70 | 38.6 | 2821.09 |
210/50 | 20.9 | 969.34 | 800/100 | 39.1 | 3038.27 |
All Aluminum Alloy Conductor Basic parameter | |||||
JLHA1 JLHA2 | JLHA3 JLHA4 | ||||
Specification | Outer Diameter of Cable | Approximate weight | Specification | Outer Diameter of Cable | Approximate weight |
16 | 5.13 | 45.11 | 25 | 6.39 | 69.77 |
20 | 5.49 | 51.56 | 35 | 7.50 | 96.39 |
25 | 6.39 | 69.77 | 40 | 8.10 | 112.37 |
30 | 6.87 | 80.70 | 50 | 9.00 | 138.71 |
35 | 7.56 | 97.79 | 70 | 10.8 | 199.79 |
45 | 8.67 | 128.62 | 95 | 12.5 | 266.48 |
50 | 9.06 | 140.39 | 100 | 13.0 | 280.21 |
70 | 10.7 | 196.43 | 120 | 14.3 | 339.06 |
75 | 10.9 | 202.87 | 125 | 14.5 | 350.27 |
95 | 12.5 | 266.48 | 150 | 15.8 | 414.72 |
120 | 13.9 | 322.25 | 185 | 17.5 | 512.79 |
145 | 15.5 | 400.71 | 200 | 18.3 | 560.43 |
150 | 15.9 | 420.32 | 210 | 18.8 | 588.45 |
185 | 17.6 | 515.59 | 240 | 20.0 | 669.71 |
210 | 18.8 | 588.45 | 250 | 20.5 | 700.54 |
230 | 19.7 | 644.49 | 275 | 21.6 | 773.39 |
240 | 20.1 | 672.51 | 280 | 21.7 | 781.80 |
300 | 22.5 | 837.84 | 300 | 22.4 | 835.04 |
360 | 24.7 | 1014.37 | 315 | 23.0 | 882.67 |
400 | 26.0 | 1120.86 | 335 | 23.8 | 941.52 |
465 | 27.9 | 1288.98 | 340 | 23.9 | 952.73 |
500 | 29.1 | 1401.07 | 400 | 26.0 | 1120.86 |
520 | 29.5 | 1451.51 | 425 | 26.8 | 1193.71 |
580 | 31.2 | 1611.23 | 450 | 27.6 | 1263.77 |
630 | 32.7 | 1768.15 | 500 | 29.1 | 1409.48 |
650 | 33.0 | 1807.38 | 530 | 30.0 | 1487.94 |
720 | 35.0 | 2031.55 | 560 | 30.7 | 1569.20 |
800 | 36.8 | 2244.51 | 630 | 32.7 | 1768.15 |
675 | 33.8 | 1888.64 | |||
710 | 34.7 | 1989.52 | |||
800 | 36.8 | 2244.51 |
JL(JL1,JL2,JL3)/LHA1 Aluminum Conductor Alloy Reinforced Basic parameter |
||
Specification | Outer Diameter of Cable | Approximate weight |
25/20 | 8.34 | 118.92 |
40/30 | 10.5 | 187.47 |
60/45 | 13.2 | 297.71 |
80/50 | 14.9 | 368.16 |
105/60 | 16.8 | 470.27 |
130/140 | 21.4 | 758.42 |
135/80 | 18.9 | 593.36 |
135/140 | 21.6 | 772.42 |
135/145 | 21.7 | 780.81 |
165/170 | 23.8 | 940.34 |
165/175 | 23.9 | 951.53 |
170/95 | 21.1 | 739.68 |
210/220 | 26.8 | 1192.21 |
210/230 | 27.6 | 1262.18 |
235/250 | 28.7 | 1368.52 |
260/275 | 30.2 | 1516.85 |
265/60 | 23.4 | 906.83 |
270/420 | 34.2 | 1937.11 |
307/470 | 36.3 | 2177.85 |
335/80 | 26.4 | 1155.14 |
345/530 | 38.5 | 2454.98 |
365/165 | 30.0 | 1485.29 |
375/85 | 27.9 | 1293.28 |
415/95 | 29.5 | 1441.20 |
455/205 | 33.5 | 1854.52 |
465/110 | 31.2 | 1616.24 |
465/210 | 33.8 | 1885.28 |
505/65 | 31.1 | 1594.69 |
515/230 | 35.6 | 2092.27 |
535/240 | 36.2 | 2159.39 |
570/390 | 40.3 | 2677.54 |
580/260 | 37.7 | 2352.41 |
630/430 | 42.5 | 2979.70 |
650/295 | 40.0 | 2640.52 |
665/300 | 40.5 | 2710.44 |
705/485 | 45.0 | 3343.43 |
745/335 | 42.8 | 3029.31 |
790/540 | 47.5 | 3732.32 |
800/550 | 47.9 | 3785.48 |
JLHA3/G1A (G2A ,G3A)&JLHA4/G1A (G2A ,G3A) Aluminum Alloy Conductor Steel Reinforced Basic parameter |
|||||
Specification | Outer Diameter of Cable | Approximate weight | Specification | Outer Diameter of Cable | Approximate weight |
10/2 | 4.50 | 43.75 | 240/40 | 21.7 | 976.77 |
16/3 | 5.55 | 66.35 | 240/55 | 22.4 | 1119.73 |
35/6 | 8.16 | 143.66 | 300/15 | 23.0 | 953.01 |
50/8 | 9.60 | 198.81 | 300/20 | 23.4 | 1014.02 |
50/30 | 11.6 | 375.72 | 300/25 | 23.8 | 1071.37 |
70/10 | 11.4 | 279.74 | 300/40 | 23.9 | 1147.70 |
70/40 | 13.6 | 516.58 | 300/50 | 24.3 | 1225.85 |
95/15 | 13.6 | 385.29 | 300/70 | 25.2 | 1417.47 |
95/20 | 13.9 | 414.88 | 400/20 | 26.9 | 1302.65 |
95/55 | 16.0 | 714.82 | 400/25 | 26.6 | 1312.36 |
120/7 | 14.5 | 385.63 | 400/35 | 26.8 | 1367.18 |
120/20 | 15.1 | 473.45 | 400/50 | 27.6 | 1529.74 |
120/25 | 15.7 | 532.89 | 400/65 | 28.0 | 1631.93 |
120/70 | 18.0 | 904.67 | 400/95 | 29.1 | 1879.75 |
150/8 | 16.0 | 469.77 | 460/60 | 29.8 | 1778.19 |
150/20 | 16.7 | 557.51 | 500/35 | 30.1 | 1674.19 |
150/25 | 17.1 | 608.54 | 500/45 | 30.0 | 1710.46 |
150/35 | 17.5 | 683.45 | 500/65 | 31.0 | 1920.55 |
185/10 | 18.0 | 593.31 | 630/45 | 33.8 | 2105.13 |
185/25 | 18.9 | 715.03 | 630/55 | 34.3 | 2237.78 |
185/30 | 18.9 | 740.84 | 630/80 | 34.5 | 2365.74 |
185/45 | 19.6 | 858.61 | 710/50 | 35.9 | 2375.08 |
210/10 | 19.0 | 660.83 | 710/90 | 36.8 | 2693.98 |
210/25 | 20.0 | 799.56 | 720/50 | 36.2 | 2427.02 |
210/35 | 20.4 | 865.59 | 800/55 | 38.2 | 2688.92 |
210/50 | 20.9 | 970.85 | 800/70 | 38.6 | 2826.94 |
240/30 | 21.6 | 933.95 | 800/100 | 39.1 | 3041.69 |
2. Our Factory
3. Our Honor
4. Contact Details
Jessica Wang | Taifeng Cable Co., Ltd.
Add.: Heda Center, No.177 Tailiu Road, Shibei District, Qingdao, China
Factory Add.: No.1 Taifeng Road, Dacaozhuang Administrative Zone, Xingtai City, Hebei Province, China
Tel: 0086 532 85611663
Phone: 0086 15192706553
Website: taifengcable.en.
We are China Aluminum Alloy Steel Reinforced Overhead Power Transmission Line ABC Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Aerial Bundle Cable Products
NFC 33-209 Standard Aerial Bundle Cable
ABC (Aerial Bundle Cable) with Duplex/Triplex/Quadruplex Service Drop- Aluminum Conductor
0.6/1kv Aerial Bundle Cable (IEC, ASTM, Sans, NFC Standards)
0.6/1kv Aluminum Conductor Cable 95mm ABC Cable
ASTM ACSR Conductor Used as Bare Overhead Transmission
Aluminium Conductors Steel Reinforced (ASTM B 232)
Popular taifengcable Products
High Standard Flexible Copper Conductor PVC Insulation Sheath Home Use Electrical Wire
Low Voltage PVC/XLPE Insulated Aluminum/Copper Conductor 4*120mm2 ABC Cable
XLPE Insulated PVC Sheathed Copper Electric Wire Flexible Use Control Power Cable
Flexible PVC Insulated PE Sheath Braided Mechanical Control Cable
Stranded Galvanized Building Wire PVC Insulated Thermoplastic Insulation Electric Wire
Popular Triplex Cable Products
0.6/1kv Service Drop ABC Cable for Overhead Transmission
150mm 3c Quadruplex Aerial Triplex ABC Drop Cable
Overhead Duplex, Triplex, Quadruplex Aluminum Cable
Aluminum Conductor Steel Reinforced Overhead ACSR Aerial Bundle Cable
Overhead Insulated Aerial Bundle Service Drop Triplex ABC Cable
Duplex/Triplex/Quadruplex AAAC/ACSR/AAC/XLPE Aerial Bunched Cable
Popular Twisted Aluminum Cable Products
Aluminum Product Overhead Power Cable
Three Cores Twisted Service Drop Aluminum Electric Cable ABC Cable
Duplex Triplex Quadruplex Service Drop Aluminum Conductor ABC Cable
AAAC All Aluminum Alloy Conductor Overhead Power Aerial Bundle Cable
AAC All Aluminum Conductor Overhead Power Transmission Aerial Bundled Cable
Manufacturer ACSR (Aluminum Conductor Steel Reinforced) for Power Transmission Line
Tags: Aerial Bundle Cable, taifengcable, Triplex Cable, Twisted Aluminum Cable